EN 1366-11:2018

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire resistance tests for service installations - Part 11: Fire protective systems for cable systems and associated components

Published date

09-05-2018

Superseded date

14-01-2022

Superseded by

EN 1366-11:2018+A1:2021

Sorry this product is not available in your region.
Summarise this standard

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (informative) - Thermocouples inside the fire
        protective systems
Annex B (informative) - Preheating
Annex C (informative) - Performance criteria for
        communication/data cables
Bibliography

This European Standard describes the method to evaluate the performance of protective systems for electrical cable and busbar systems in order to maintain the circuit integrity under fire conditions to classify the protective system according to EN 13501 3 for the P classification. The test examines the behaviour of cable protection systems exposed to fire from outside. The tests specified in this standard are not aimed for assessing the performance of the fire protective system and the penetration seal for maintaining the requirements of the penetrated wall or ceiling (classification E / I).This method is very different to EN 50200 for the PH classification and also to IEC 60331 11, IEC 60331 21, IEC 60331 23, and IEC 60331 25, which are not designed for fire protective systems for electrical cable systems.This standard should be used in conjunction with EN 1363 1.The test results apply to fire protective systems for electrical cable systems rated for voltages up to 1 kV.The test procedure should also be used to determine the performance of protective systems for use with data and optical cables, however, verification procedures for such cables are still under development. Proposals are given in Annex C.The protective system may include ventilation devices, inspection hatches, fixed or removable lids etc.The tests specified in this standard are not aimed for assessing the performance of sprayed or painted coatings (e.g. intumescent or ablative coating, plastic film, epoxy resin) and similar protective layers (e.g. wrap, bandage) applied directly on the cables or bus bars as fire protective system. Also, cables and bus bars with intrinsic resistance to fire, and without fire protective systems around, are excluded (see CENELEC standard EN 50577).This test method is not applicable for cabinets for electrical accessory containing bus systems, relays or similar.Dieses Prüfverfahren gilt nicht für Schaltschränke für elektrische Zubehörteile wie Bussysteme, Relais u. ä.

Committee
CEN/TC 127
DevelopmentNote
Supersedes PREN 1366-11. (05/2018)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
NS EN 1366-11:2018 Identical
DIN EN 1366-11:2018-07 Identical
NEN-EN 1366-11:2018 en Identical
PN-EN 1366-11:2018-06 Identical
I.S. EN 1366-11:2018 Identical
SS-EN 1366-11:2018 Identical
NF EN 1366-11:2018 Identical
BS EN 1366-11:2018 Identical
UNE-EN 1366-11:2019 Identical

Sorry this product is not available in your region.