Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods

Published date

21-05-2014

Sorry this product is not available in your region.
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Technical requirements
5 Process control
6 Performance requirements
7 Sound power
8 Packaging, marking and labelling
9 Information to be supplied by the manufacturer
10 Service and local environment
Annex A (normative) - Test instrumentation
Annex B (normative) - Leak test cycle
Annex C (normative) - Sterilizer chamber profile testing
Annex D (normative) - Microbiological test for EO sterilizers
Annex E (informative) - Environmental aspects
Annex ZA (informative) - Relationship between this European
         Standard and the Essential Requirements of
         EU Directive 93/42/EEC on medical devices
Bibliography

This European Standard specifies the requirements and the relevant tests for automatically controlled sterilizers employing ethylene oxide (EO) gas as the sterilant, either as a pure gas or a mixture with other gases, being used for the sterilization of medical devices and their accessories.This European Standard specifies requirements for ethylene oxide sterilizers (EO-sterilizers) working at super or sub-atmospheric pressure for:- the performance and design of sterilizers to ensure that the process is capable of sterilizing medical devices;- the equipment and controls of these sterilizers necessary for the validation and routine control of the sterilization processes.The test loads described in this European Standard are selected to represent a number of loads for the evaluation of the performance of EO sterilizers for medical devices. However, specific loads may require the use of other test loads.This European Standard does not specify those tests which are necessary to determine the probability of a processed product being sterile, nor the routine quality control tests required prior to release of sterile product. These topics are addressed in prEN ISO 11135:2012.This European Standard does not specify requirements for occupational safety associated with the design and operation of EO sterilization facilities.NOTE 1For further information on safety, see examples in the Bibliography. National or regional regulations can exist.This European Standard does not cover sterilizers which employ the injection of EO or mixtures containing EO directly into packages or into a flexible chamber.NOTE 2See EN ISO 14937.This European Standard is not intended as a checklist for suitability of an existing EO sterilizer when assessing compliance with prEN ISO 11135:2012. This standard is not intended to be applied retrospectively.This European Standard does not cover analytical methods for determining levels of residual EO and/or its reaction products.NOTE 3For further information see ISO 10993 7.

Committee
CEN/TC 102
DevelopmentNote
Supersedes PREN 1422. (06/2014)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

Standards Relationship
NF EN 1422 : 2014 Identical
NS EN 1422 : 2014 Identical
PN EN 1422 : 2014 Identical
I.S. EN 1422:2014 Identical
NEN EN 1422 : 2014 Identical
DIN EN 1422:2014-08 Identical
BS EN 1422:2014 Identical
NBN EN 1422 : 2014 Identical
UNE-EN 1422:1998 Identical
DIN EN 1422:1997-11 Identical
UNE-EN 1422:2014 Identical