EN 50091-1-2 : 98 COR 1 99

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Published date

12-01-2013

Superseded date

16-01-2003

Sorry this product is not available in your region.
Summarise this standard

1 General
1.1 Scope
1.2 Normative references
1.3 Definitions
1.4 General requirements
1.5 General conditions for tests
1.6 Components
1.7 Power interfaces
1.8 Marking and instructions
2 Fundamental design requirements
2.1 Protection against electric shock and energy hazards
2.2 Insulation
2.3 Safety Extra-Low Voltage (SELV) Circuits
2.4 Limited current circuits
2.5 Provisions for protective earthing
2.6 A.C. and d.c. power isolation
2.7 Overcurrent and earth fault protection
2.8 Protection of service personnel
2.9 Clearances, creepage distances and distances through
    insulation
2.10 External signalling circuits
2.11 Limited power source
2.12 Protection of the applied load
2.13 Connection to other equipment
3 Wiring, connections and supply
3.1 General
3.2 Connection to power sources
3.3 Wiring terminals for external power conductors
4 Physical requirements
4.1 Stability and mechanical hazards
4.2 Mechanical strenght and stress relief
4.3 Construction details
4.4 Resistance to fire
4.5 Battery location
5 Thermal and electrical requirements
5.1 Heating
5.2 Earth leakage current
5.3 Electric strength
5.4 Abnormal operating and fault conditions
Annex A (normative) Test for resistance to heat and fire
Annex B (normative) Motor test under abnormal conditions
Annex C (normative) Transformers
Annex D (normative) Measuring instruments for earth
        leakage current test
Annex E (normative) Temperature rise of a winding
Annex F (normative) Measurements of creepage
Annex G (normative) Earth leakage current for UPS intended
        to be connected directly to IT power systems
Annex H (informative) Guidance on protection against ingress
        of water and foreign objects
Annex J (informative) Tables of electrochemical potentials
Annex K (normative) Thermal controls
Annex L (normative) Backfeed protection test
Annex M (normative) Reference load conditions
Annex N (normative) Ventilation of battery compartments
Annex P (normative) Minimum and maximum cross-sections
        for copper conductor
Annex Q (informative) A-Deviations
Annex R (normative) Special national conditions

Applicable to electronic indirect a.c. convertor systems with an electrical energy storage device in the d.c. link. Main function of the UPS covered is to ensure continuity of an alternative power source. Uninterruptible power system may also serve to improve the quality of the power source by keeping it within specified characteristics. Applies to UPS for use on distribution systems up to 1 000 V a.c. which are movable, stationary, fixed and for building in; intended to be installed in restricted access locations and details requirements for safety of service personnel. To ensure the safety of installed UPS both as a single UPS unit or as a system of interconnected UPS units, subject to installing, operating and maintaining the UPS in the manner prescribed by the manufacturer.

Committee
TC 22X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy