EN 50311:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Railway applications - Rolling stock - D.C. supplied electronic ballasts for lighting fluorescent lamps
04-06-2003
01-04-2016
Foreword
Introduction
1 Scope
2 Normative references
3 Definitions
3.1 General terms
3.2 Lamps and characteristics
4 Classification
5 Characteristics
5.1 Rated voltages
5.2 Overvoltages
5.3 Type of fluorescent lamps
6 Product information
6.1 Nature of information
6.2 Marking
6.3 Instructions for storage, installation operation and
maintenance
7 Normal service conditions
7.1 Temperature
7.2 Other conditions
8 Constructional and performance requirements
8.1 Constructional requirements
8.2 Performance requirements
8.3 Safety requirements
9 Tests
9.1 Test conditions
9.2 Kinds of tests
9.3 Verification of constructional and performance requirements
Annex A (informative) Types of lamps
Annex B (informative) Electronic ballast for lamps up to 40 W
Annex C (informative) Electronic ballast for lamps up to 40 W
Annex D (informative) Electronic ballast for lamps up to 15 W
Annex E (informative) Electronic ballast for lamps up to 10 W
Annex F (informative) Electronic ballast for lamps up to 10 W
Annex G (informative) Basic schematic diagrams
Annex H (informative) Correspondence with EN 60924 requirements
This standard specifies the performance and constructional requirements, and associated tests, for d.c. supplied electronic ballasts used to supply fluorescent lamps for lighting on railway rolling stock. Its requirements replace those of EN 60925 for all railway rolling stock applications and precise and complete those of EN 60924 for the specific needs of railway rolling stock applications.This standard applies to electronic ballasts-supplying pre-heated cathode fluorescent lamps without integrated starters, tubular or single capped, according to EN 60081 and EN 60901 respectively,-having a single and non adjustable luminous flux level.It does not apply to electronic ballasts supplying non pre-heated cathode lamps and/or lamps with integrated starters.
| Committee |
CLC/TC 9X
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| BS EN 50311:2003 | Identical |
| CEI EN 50311 : 2004 | Identical |
| NBN EN 50311 : 2003 | Identical |
| NEN EN 50311 : 2003 | Identical |
| DIN EN 50311 : 2004 | Identical |
| VDE 0115-450 : 2004 | Identical |
| I.S. EN 50311:2003 | Identical |
| NF EN 50311 : 2003 | Identical |
| PN EN 50311 : 2003 | Identical |