EN 50377-5-1:2003
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 5-1: Type EC terminated on IEC 60793-2 category B1.1 singlemode fibre
12-03-2003
18-04-2018
1 Scope
1.1 Product definition
1.2 Intermateability
1.3 Operating environment
1.4 Reliability
1.5 Quality assurance
2 Normative references
3 Description
3.1 Plug
3.2 Adapter
3.3 Materials
3.4 Dimensions
3.5 Colour and marking
4 Variants
4.1 Terminated plug
4.2 Adapter
4.3 Identification of variants
5 Dimensional requirements
5.1 Outline dimensions
5.1.1 Plug variants
5.1.2 Adapter variants
5.2 Mating face and other limit dimensions
5.2.1 Plug
5.2.2 Adapter
6 Tests
6.1 Sample size
6.2 Test and measurement methods
6.3 Test sequence
6.4 Pass/fail criteria
7 Test report
8 Testing requirements
8.1 Dimensional requirements
8.2 Optical performance requirements
8.3 Mechanical performance requirements
8.4 Environmental performance requirements
Annex A (normative) Sample size and product sourcing requirements
Annex B (normative) Reference connector details
1.1Product definitionThis standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled singlemode EC connector set (plug adapter plug) must meet in order for it to be categorised as an EN product specification.Since different variants and grades of performance are permitted, product marking details are given in 3.5. 1.2IntermateabilityAll products conforming to the requirements of this standard will intermate, the resulting level of random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will be true irrespective of the manufacturing source(s) of the product.In all cases, the intermating of plug variants having different attenuation grades will result in an uncertain level of random attenuation performance.Similarly, the intermating of plug variants with suffix A, with plug variants with suffix C, will result in an uncertain level of random attenuation performance.1.3Operating environmentThe tests selected combined with the severities and durations are representative of an external weather protected environment defined by–ES 200 671: external weather protected environment defined by ETS 300 019-1-3 classes 3.3, 3.4 and 3.5–EN 61753-2-1 category U: uncontrolled environment.1.4ReliabilityWhilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this standard does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme.1.5Quality assuranceCompliance with this standard does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme.
| Committee |
CLC/TC 86BXA
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| Standards | Relationship |
| NF EN 50377-5-1 : 2003 | Identical |
| NBN EN 50377 5-1 : 2004 | Identical |
| CEI EN 50377-5-1 : 2005 | Identical |
| PN EN 50377-5-1 : 2004 | Identical |
| NEN EN 50377-5-1 : 2003 | Identical |
| I.S. EN 50377-5-1:2003 | Identical |
| DIN EN 50377-5-1:2003-09 | Identical |
| BS EN 50377-5-1:2003 | Identical |
| UNE-EN 50377-5-1:2003 | Identical |