1 Scope
2 Normative references
3 Physical quantities, units and constants
   3.1 Quantities
   3.2 Constants
4 Terms and definitions
5 Applicability of compliance assessment methods
   5.1 Introduction
   5.2 Assessment procedure
   5.3 Representative antennas for each service
6 SAR measurement and calculation
   6.1 Whole-body SAR implicit compliance
   6.2 SAR compliance
7 Electromagnetic field measurement
   7.1 Measuremen
   7.2 Uncertainty
8 Electromagnetic field calculation
   8.1 Field regions
   8.2 Calculation models
9 Contact currents measurement and calculation
10 Induced current measurement and calculation
Annex A (normative) Field volume measurement
Annex B (informative) Compliance boundary examples

This standard applies to a broadcast transmitter operating in the frequency range 30 MHz to 40 GHz when put on the market. The objective of the standard is to specify, for such equipment operating in typical conditions, the method for assessment of compliance distances according to the basic restrictions (directly or indirectly via compliance with reference levels) related to human exposure to radio frequency electromagnetic fields.

Committee
CLC/TC 106X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Standards Relationship
DIN EN 50420 : 2007 Identical
NBN EN 50420 : 2007 Identical
UNE-EN 50420:2009 Identical
BS EN 50420:2006 Identical
PN EN 50420 : 2006 Identical
NEN EN 50420 : 2006 Identical
VDE 0848-420 : 2007 Identical
NF EN 50420 : 2006 Identical
CEI EN 50420 : 2007 Identical
I.S. EN 50420:2006 Identical
SN EN 50420 : 2006 Identical
UNE-EN 50420:2006 Identical

CEI EN 50496 : 2010 DETERMINATION OF WORKERS' EXPOSURE TO ELECTROMAGNETIC FIELDS AND ASSESSMENT OF RISK AT A BROADCAST SITE
I.S. EN 50421:2006 PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF STAND ALONE BROADCAST TRANSMITTERS WITH THE REFERENCE LEVELS OR THE BASIC RESTRICTIONS RELATED TO PUBLIC HUMAN EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS (30 MHZ - 40 GHZ)
06/30157890 DC : 0 BS EN 50496 - DETERMINATION OF WORKERS' EXPOSURE TO ELECTROMAGNETIC FIELDS AND ASSESSMENT OF RISK AT A BROADCAST SITE
EN 50421:2006 Product standard to demonstrate the compliance of stand alone broadcast transmitters with the reference levels or the basic restrictions related to public human exposure to radio frequency electromagnetic fields (30 MHz - 40 GHz)
BS EN 50421:2006 Product standard to demonstrate the compliance of stand alone broadcast transmitters with the reference levels or the basic restrictions related to public human exposure to radio frequency electromagnetic fields (30 MHz to 40 GHz)
04/30118438 DC : DRAFT AUG 2004 EN 50421 - PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF STAND ALONE BROADCAST TRANSMITTERS WITH THE REFERENCE LEVELS OR THE BASIC RESTRICTIONS RELATED TO PUBLIC EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS (30 MHZ TO 40 GHZ)
BS EN 50496:2008 Determination of workers\' exposure to electromagnetic fields and assessment of risk at a broadcast site
CEI EN 50421 : 2007 PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF STAND ALONE BROADCAST TRANSMITTERS WITH THE REFERENCE LEVELS OR THE BASIC RESTRICTIONS RELATED TO PUBLIC HUMAN EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS (30 MHZ - 40 GHZ)
I.S. EN 50496:2018 DETERMINATION OF WORKERS' EXPOSURE TO ELECTROMAGNETIC FIELDS AND ASSESSMENT OF RISK AT A BROADCAST SITE
EN 50496:2018 Determination of workers' exposure to electromagnetic fields and assessment of risk at a broadcast site

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
EN 50421:2006 Product standard to demonstrate the compliance of stand alone broadcast transmitters with the reference levels or the basic restrictions related to public human exposure to radio frequency electromagnetic fields (30 MHz - 40 GHz)
IEEE C95.1-2005 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz
EN 50413 : 2008 AMD 1 2013 BASIC STANDARD ON MEASUREMENT AND CALCULATION PROCEDURES FOR HUMAN EXPOSURE TO ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more