EN 50502:2015
Current
The latest, up-to-date edition.
Railway applications - Rolling stock - Electric equipment in trolley buses - Safety requirements and current collection systems
07-08-2015
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Voltages and classification of the voltage bands
5 Trolley bus construction
6 Checks and tests
Annex A (normative) - Constructional detailed provisions
Annex B (normative) - Trolley buses - Current collection
system for overhead contact lines
Annex C (normative) - Constructional requirements for
current collection systems
Annex D (informative) - Open door interlocking
Bibliography
This European Standard applies to electrical systems on board of vehicles of the type trolleybus, as defined in 3.1, fed with a nominal line voltage (Un) between 600 V d.c. and 750 V d.c.This European Standard defines the requirements and constructional hints, especially to avoid electrical danger to the public and to staff. Where special requirements are existing for trolleybuses, hints are given for mechanical and functional safety as well as for protection against fire.This European Standard covers vehicles intended for public transport of persons. This Standard applies to:-trolleybuses,-buses with current rail for guidance in the road surface,-guided buses with bipolar roof current collector.This European Standard does not apply to:a)electric driven vehicles with only internal power supply:1)hybrid vehicles,2)diesel - electric vehicles,3)fuel - cell vehicles,4)battery vehicles,b)vehicles with safe protective bonding:1)rubber tyred commuter trains,2)guided buses with supply by a separate current rail,3)rail guided buses with unipolar roof current collector,c)vehicles operated outside publicly accessible areas:1)electric driven lorries on motorways.Guidance and current rails are special solutions and at this time are not under standardization like trolleybus current collectors and overhead contact lines (OCL).It refers mainly to earthed networks, but reference is made also to galvanically insulated networks.Annex A is related to detailed design features for trolleybuses.Annexes B and C are related to the connection systems. The detailed scope of these annexes is given in Annex B.
| Committee |
CLC/TC 9X
|
| DevelopmentNote |
Supersedes CLC/TS 50502 and PREN 50502. (08/2015)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NEN EN 50502 : 2015 | Identical |
| NF EN 50502 : 2016 | Identical |
| DIN EN 50502:2016-03 | Identical |
| OVE EN 50502/AC:2020 01 01 | Identical |
| CEI EN 50502:2018 | Identical |
| CEI EN 50502 : 2016 | Identical |
| I.S. EN 50502:2015 | Identical |
| NBN EN 50502 : 2015 | Identical |
| PN EN 50502 : 2015 | Identical |
| VDE 0115-502:2016-03 | Identical |
| BS EN 50502:2015 | Identical |
| ONORM OVE EN 50502 : 2016 | Identical |
| UNE-EN 50502:2016 | Identical |