EN 60068-2-6:2008
Current
The latest, up-to-date edition.
Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
29-02-2008
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements for testing
4.1 Required characteristics
4.1.1 Basic motion
4.1.2 Spurious motion
4.1.3 Signal tolerance
4.1.4 Vibration amplitude tolerances
4.1.5 Frequency tolerances
4.1.6 Sweep
4.2 Control strategy
4.2.1 Single/multipoint control
4.2.2 Multi-reference control
4.3 Mounting
5 Severities
5.1 Frequency range
5.1.1 Lower frequency f[1] Hz
5.1.2 Upper frequency f[2] Hz
5.2 Vibration amplitude
5.3 Duration of endurance
5.3.1 Endurance by sweeping
5.3.2 Endurance at fixed frequencies
6 Preconditioning
7 Initial measurements
8 Testing
8.1 General
8.2 Vibration response investigation
8.3 Endurance procedures
8.3.1 Endurance by sweeping
8.3.2 Endurance at fixed frequencies
9 Intermediate measurements
10 Recovery
11 Final measurements
12 Information to be given in the relevant specification
13 Information to be given in the test report
Annex A (informative) Guide to test Fc
Annex B (informative) Examples of severities primarily intended
for components
Annex C (informative) Examples of severities primarily intended
for equipment
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Gives a method of test which provides a standard procedure to determine the ability of components, equipment and other articles, hereinafter referred to as specimens, to withstand specified severities of sinusoidal vibration. If an item is to be tested in an unpackaged form, that is without its packaging, it is referred to as a test specimen. However, if the item is packaged then the item itself is referred to as a product and the item and its packaging together are referred to as a test specimen. The purpose of this test is to determine any mechanical weakness and/or degradation in the specified performance of specimens and to use this information, in conjunction with the relevant specification, to decide upon the acceptability of the specimens. In some cases, the test method may also be used to demonstrate the mechanical robustness of specimens and/or to study their dynamic behaviour. Categorization of components can also be made on the basis of a selection from within the severities quoted in the test. The major changes with regard to the previous edition concern: - Reference to the latest version of IEC 60068-2-47:Mounting - Simplification of the layout of the standard by replacing some tables with text. - Addition of the test report requirements (see Clause 13).
| Committee |
CLC/SR 104
|
| DevelopmentNote |
Supersedes HD 323.2.6. (03/2008)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| DIN EN 60068-2-6:2008-10 | Identical |
| VDE 0468-2-6:2008-10 | Identical |
| CEI EN 60068-2-6 : 2009 | Identical |
| I.S. EN 60068-2-6:2008 | Identical |
| DIN EN 60068-2-6 : 1996 | Identical |
| NF EN 60068 2-6 : 2008 | Identical |
| NEN 10068-2-6 : 1995 | Identical |
| NEN EN IEC 60068-2-6 : 2008 | Identical |
| PN EN 60068-2-6 : 2008 | Identical |
| BS EN 60068-2-6:2008 | Identical |
| NBN EN 60068 2-6 : 2008 | Identical |
| UNE-EN 60068-2-6:2008 | Identical |
| BS EN 61800-7-301:2016 | Identical |