EN 60695-11-5:2017

Current

Current

The latest, up-to-date edition.

Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

Published date

16-06-2017

Sorry this product is not available in your region.
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Purpose of the test
5 Description of the test apparatus
6 Test specimen
7 Flame application times
8 Conditioning and test conditions
9 Test procedure
10 Observations and measurements
11 Evaluation of test results
12 Information to be given in the relevant specification
13 Test report
Annex A (normative) - Confirmatory test arrangement
Annex B (informative) - Example of a product
        committee specification
Annex C (informative) - Comparison of results of
        confirmatory tests using propane and butane as fuel
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess by a simulation technique the fire hazard. It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating materials or other combustible materials. This first edition of EN 60695-11-5 cancels and replaces the second edition of EN 60695-2-2, issued in 1991 and its amendment 1 (1994). It also constitutes a technical revision. The structure of this standard remains essentially the same with some major new changes and concepts added: - The scope has been broadened to allow this test method to also simulate the effects of small flames from outside the equipment. - A new concept has been added which allows the burner to be moved during the test to avoid dripping material from falling onto the tip of the burner tube. - The burner tube material is now a referenced source. - The reference for the copper block material has changed - the ISO publication (ISO 1337) has been withdrawn with no replacement. A new callout is now used. - Informative Annex B and a bibliography have been added. It has the status of a basic safety publication in accordance with IEC Guide 104.

Committee
CLC/SR 89
DevelopmentNote
Supersedes EN 60695-2-2 (03/2005)