Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

EN 61000-4-20:2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides

Published date

05-11-2010

Superseded date

08-04-2022

Superseded by

EN IEC 61000-4-20:2022

Sorry this product is not available in your region.
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms, definitions and abbreviations
4 General
5 TEM waveguide requirements
6 Overview of EUT types
7 Laboratory test conditions
8 Evaluation and reporting of test results
Annex A (normative) - Emission testing in TEM
        waveguides
Annex B (normative) - Immunity testing in TEM
        waveguides
Annex C (normative) - HEMP transient testing in TEM
        waveguides
Annex D (informative) - TEM waveguide characterization
Annex E (informative) - Calibration method for E-field
        probes in TEM waveguides
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications
Bibliography

IEC 61000-4-20:2010 relates to emission and immunity test methods for electrical and electronic equipment using various types of transverse electromagnetic (TEM) waveguides. These types include open structures (for example, striplines and electromagnetic pulse simulators) and closed structures (for example, TEM cells). These structures can be further classified as one-, two-, or multi-port TEM waveguides. The frequency range depends on the specific testing requirements and the specific TEM waveguide type. The object of this standard is to describe:- TEM waveguide characteristics, including typical frequency ranges and EUT-size limitations;- TEM waveguide validation methods for EMC tests;- the EUT (i.e. EUT cabinet and cabling) definition;- test set-ups, procedures, and requirements for radiated emission testing in TEM waveguides and- test set-ups, procedures, and requirements for radiated immunity testing in TEM waveguides.IEC 61000-4-20:2010 does not intend to specify the tests to be applied to any particular apparatus or system(s). The main intention of this standard is to provide a general basic reference for all interested product committees of the IEC. For radiated emissions testing, product committees should select emission limits and test methods in consultation with CISPR standards. For radiated immunity testing, product committees remain responsible for the appropriate choice of immunity tests and immunity test limits to be applied to equipment within their scope. This standard describes test methods that are separate from those of IEC 61000-4-3. This second edition cancels and replaces the first edition published in 2003 and its amendment 1 (2006), and constitutes a technical revision. It has the status of a basic EMC publication in accordance with IEC Guide 107. The main changes with respect to the first edition of this standard and its amendment are the following: - consistency of terms (e.g. test, measurement, etc.) has been improved;- clauses covering test considerations, evaluations and the test report have been added;- references to large TEM waveguides have been eliminated;- a new informative annex has been added to deal with calibration of E-field probes.

Committee
CLC/TC 210
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Sorry this product is not available in your region.