Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

EN 62305-2:2012

Current

Current

The latest, up-to-date edition.

Protection against lightning - Part 2: Risk management

Published date

18-05-2012

Sorry this product is not available in your region.
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Explanation of terms
5 Risk management
6 Assessment of risk components
Annex A (informative) - Assessment of annual
        number N of dangerous events
Annex B (informative) - Assessment of probability
        P[X] of damage
Annex C (informative) - Assessment of amount of
        loss L[X]
Annex D (informative) - Evaluation of costs of loss
Annex E (informative) - Case study
Bibliography

IEC 62305-2:2010(E) is applicable to risk assessment for a structure due to lightning flashes to earth. Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure allows the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit. This second edition cancels and replaces the first edition, published in 2006, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: 1) Risk assessment for services connected to structures is excluded from the scope. 2) Injuries of living beings caused by electric shock inside the structure are considered. 3) Tolerable risk of loss of cultural heritage is lowered from 10-3 to 10-4. The value of tolerable risk of loss of economic value (RT = 10-3) is introduced, to be used when data for cost/benefit analysis are not available. 4) Extended damage to surroundings structures or to the environment is considered. 5) Improved equations are provided for evaluation of: - collection areas relevant to flashes nearby a structure, - collection areas relevant to flashes to and nearby a line, - probabilities that a flash can cause damage, - loss factors even in structures with risk of explosion, - risk relevant to a zone of a structure, - cost of loss. 6) Tables are provided to select the relative amount of loss in all cases. 7) Impulse withstand voltage level of equipments was extended down to 1 kV.

Committee
CLC/TC 81X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Sorry this product is not available in your region.