EN 867-5:2001

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Non-biological systems for use in sterilizers - Part 5: Specification for indicator systems and process challenge devices for use in performance testing for small sterilizers Type B and Type S

Published date

29-08-2001

Withdrawn date

28-02-2002

Sorry this product is not available in your region.
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
6 Marking, labelling and packaging
Annex A (normative) Small steam exposure apparatus and steam
        for test purposes
Annex B (normative) Test cycles for evaluation of indicator
        performance in the porous load process challenge
        devices
Annex C (normative) Test cycles for evaluation of indicator
        systems for use in hollow load process challenge
        devices
Annex D (normative) Test cycles for evaluation of indicator
        systems for use in hollow load process challenge
        devices
Bibliography

This European Standard specifies the performance requirements and test methods for non-biological indicator systems, including the process challenge devices within which they are intended to function, to be used for testing the steam penetration performance of small steam sterilizers, Type B or Type S where ap-propriate. The test systems specified are intended for use only in small steam sterilizers Type B conforming to prEN 13060-2 and having a usable chamber space greater than 10 l and for small steam sterilizers Type S conforming to prEN 13060-4 also having a usable chamber space greater than 5 l.Non-biological indicator systems and the associate process challenge devices are specified for various types of load. The possible loads are considered in two classes: Porous loads, which can be wrapped or unwrapped, or hollow instrument loads, which also can be wrapped or unwrapped.The relevant section of this European Standard on porous loads specifies the requirements for:- a standard process challenge device to be used in the small load test for porous loads in small steam sterilizers;- an indicator system for use in the porous load process challenge device. An indicator for this purpose is a Class B indicator as described in EN 867-1.- an indicator employing an alternative process challenge device equivalent to the porous load process challenge device.The relevant section of this European Standard on hollow instruments specifies the requirements for:- hollow load process challenge devices to be used to simulate hollow instrument loads as defined in prEN 13060-4;- an indicator system, for use in one of the hollow load process challenge device, for assessing steam penetration in a wrapped load of hollow instruments. An indicator for this purpose is a Class B indicator as described in EN 867-1.The process challenge devices described in this standard are intended for use only in sterilizers of sufficient size to accommodate the proces

Committee
CEN/TC 102
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
ONORM EN 867-5 : 2001 Identical
DS EN 867-5 : 2001 Identical
NF EN 867-5 : 2001 Identical
NS EN 867-5 : 1ED 2001 Identical
I.S. EN 867-5:2001 Identical
PN EN 867-5 : 2003 Identical
NEN EN 867-5 : 2001 Identical
NBN EN 867-5 : 2001 Identical
DIN EN 867-5:2001-11 Identical
BS EN 867-5:2001 Identical
UNE-EN 867-5:2002 Identical