Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN ISO 12010:2014

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Water quality - Determination of short-chain polychlorinated alkanes (SCCPs) in water - Method using gas chromatography-mass spectrometry (GC-MS) and negative-ion chemical ionization (NCI) (ISO 12010:2012)

Published date

16-04-2014

Superseded date

30-03-2022

Superseded by

EN ISO 12010:2019

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Principle
4 Interferences
5 Reagents and standards
6 Apparatus
7 Sampling and sample pretreatment
8 Procedure
9 Expression of results
10 Test report
Annex A (informative) - Additional quality control check
        solutions
Annex B (informative) - Explanation of the calibration of the
        sum of SCCPs with multiple linear regression
Annex C (informative) - Typical GC-MS conditions
Annex D (informative) - Typical chromatograms of standard
        solutions 1 [mu]g/ml
Annex E (informative) - Presentation of goodness of fit
Annex F (informative) - Example for recoveries of quality
        assurance solutions
Annex G (informative) - Chromatogram of a real water sample
        with a sum of SCCPs concentration of 2,59 [mu]g/l
Annex H (informative) - Precision data
Bibliography

ISO 12010:2012 specifies a method for the quantitative determination of the sum of short-chain polychlorinated n‑alkanes, also known as short-chain polychlorinated paraffins (SCCPs), in the carbon bond range n-C10 to n-C13 inclusive, in mixtures with chlorine mass fractions ("contents") between 49 % and 67 %, including approximately 6 300 of approximately 8 000 congeners.This method is applicable to the determination of the sum of SCCPs in unfiltered surface water, ground water, drinking water and waste water using gas chromatography-mass spectrometry with electron capture negative ionization (GC-ECNI-MS).The method can be applied to samples containing 0,1 µg/l to 10 µg/l. Depending on the waste water matrix, the lowest detectable concentration is estimated to be >0,1 µg/l.

Committee
CEN/TC 230
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

ISO/TS 13530:2009 Water quality — Guidance on analytical quality control for chemical and physicochemical water analysis
ISO 5667-3:2012 Water quality — Sampling — Part 3: Preservation and handling of water samples
ISO 5667-1:2006 Water quality — Sampling — Part 1: Guidance on the design of sampling programmes and sampling techniques
ISO 8466-1:1990 Water quality — Calibration and evaluation of analytical methods and estimation of performance characteristics — Part 1: Statistical evaluation of the linear calibration function

Sorry this product is not available in your region.