Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

I.S. 201-3:2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: SINGLE CORE NON-SHEATHED CABLES FOR FIXED WIRING

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2001

Superseded date

11-05-2018

Superseded by

I.S. EN 50525-1:2011

$106.98
Including GST where applicable

DECLARATION
Foreword
1 Scope
2 Single core non-sheathed cable with rigid conductor
  for general purposes
  2.1 Code designation
  2.2 Rated voltage
  2.3 Construction
  2.4 Tests
  2.5 Guide to use
3 Single core non-sheathed cable with flexible conductor
  for general purposes
  3.1 Code designation
  3.2 Rated voltage
  3.3 Construction
  3.4 Tests
  3.5 Guide to use
4 Single core non-sheathed cable with solid conductor for
  internal wiring
  4.1 Code designation
  4.2 Rated voltage
  4.3 Construction
  4.4 Tests
  4.5 Guide to use
5 Single core non-sheathed cable with flexible conductor
  for internal wiring
  5.1 Code designation
  5.2 Rated voltage
  5.3 Construction
  5.4 Tests
  5.5 Guide to use
Annex A (Normative) Normative reference
Annex B (Informative) Informative reference

Specifies the particular specifications for polyvinyl chloride insulated single-core non-sheathed cables for fixed wiring of rated voltages up to and including 450/750 V.

DevelopmentNote
Together with I.S. 201, I.S. 201-1, -2, -4, -5, -7, -8, -9, -10, -11, -12, -13 supersedes I.S. HD 21-1, 21-2, 21.5, 21-7, 21.10, 21.11, 21.12 and 21.13 (08/2003)
DocumentType
Standard
Pages
18
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy
Supersedes

IEC 60228:2004 Conductors of insulated cables
I.S. 270:1988 CONDUCTORS OF INSULATED CABLES
I.S. EN 50265-2-1:1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PROCEDURES - 1 KW PRE-MIXED FLAME
I.S. HD 516:1998 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
IEC 60228A:1982 First supplement - Conductors of insulated cables - Guide to the dimensional limits of circular conductors
I.S. EN 60719:1994 CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
I.S. EN 50265-1:1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - APPARATUS

$106.98
Including GST where applicable