Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

I.S. 444:1998

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

THE USE OF STRUCTURAL TIMBER IN BUILDINGS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-1998

Superseded date

01-04-2010

Superseded by

I.S. EN 1995-1-1:2005

$129.17
Including GST where applicable
Summarise this standard

Declaration
Introduction
Section one - General
1 Scope and field of application
  1.1 Scope
  1.2 Field of application
2 References
3 Definitions
4 Symbols and marking
  4.1 Symbols for timber in strength classes
  4.2 Symbols for strength graded timber
  4.3 Symbols used to define span
  4.4 Marking
Section two - Timber properties and design principles
5 Introduction
  5.1 General
  5.2 Timber properties
  5.3 Finger jointed members
  5.4 Design principles
  5.5 Timber durability
6 Other requirements
  6.1 Fire
  6.2 Environment
Section three - Simplified design rules
7 Rules for the use of the permissible span tables
  7.1 Introduction
  7.2 Loading assumptions
  7.3 Design assumptions
  7.4 Deflection
  7.5 Member sizes
  7.6 Purlins
  7.7 Joints
  7.8 Studding
8 Rules for members not included in the permissible
  span tables
  8.1 Tiling battens
  8.2 Bridging and strutting
  8.3 Wall plates
Section four - Timber construction
9 Construction details
  9.1 General
  9.2 Notching and drilling
  9.3 Flat roofs
  9.4 Construction tolerances
Tables
1 Strength Classes - Combustion of species and visual
    strength grades
2 Strength Classes - Permissible stress and moduli
    values
3 Design Loads
4 Design criteria
5a Floor joists (domestic without partition)
5b Floor joists (office without partition)
5c Floor joists (office with fixed lightweight
    partition)
6a Ceiling joists (for pitched roofs of 20 degree to
    40 degree)
6b Ceiling joists (for pitched roofs of 20 degree to
    40 degree) supporting domestic water cistern
7a Roof rafters without intermediate purlin support
    (for roofs with pitches of 20 degree to 40 degree)
7b Roof rafters with intermediate purlin support
    lapped at purlin support (for roofs with pitches of
    20 degree to 40 degree)
7c Roof rafters with intermediate purlin support
    continuous at purlin support (for roofs with pitches
    of 20 degree to 40 degree)
8a Flat roof joists without access for fire escape or
    maintenance (for roof pitches not exceeding 10
    degree)
8b Flat roof joists with access for fire escape or
    maintenance (for roof pitches not exceeding 10
    degree)
9a Purlins for roofs with pitches of 20 degree to 40
    degree C14-C16
9b Purlins for roofs with pitches of 20 degree to 40
    degree C18-C22
9c Purlins for roofs with pitches of 20 degree to 40
    degree C24-C27
10a Studding members 44 mm x 100 mm (domestic loading)
10b Studding members 44 mm x 100 mm (office loading)
Figures
1 General view of roof structure
2 Definition of spans
3 Water cistern support
4 Floor joist details
5 Purlin span
6 Notching and drilling

Specifies timber of given species and stress grades into Strength classes and it also permits the classification by machine.

DevelopmentNote
Supersedes I.S. SR 11. (03/2003)
DocumentType
Standard
Pages
30
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition
$129.17
Including GST where applicable