IEC 60601-2-62:2013
Current
The latest, up-to-date edition.
Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
09-07-2013
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of
ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and
ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS
from ME EQUIPMENT
201.9 Protection against mechanical hazards
of ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures
and other HAZARDS
201.12 Accuracy of controls and instruments and
protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
for ME EQUIPMENT
201.14 Programmable ELECTRICAL MEDICAL SYSTEMS
(PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME systems
201.17 Electromagnetic compatibility of ME EQUIPMENT
and ME SYSTEMS
202 Electromagnetic compatibility - Requirements
and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - Targeting
Annex CC (informative) - HITU - specific risks
Annex DD (informative) - Determining regions of HITU
fields for measurement
Annex EE (informative) - Guidance in classification
according to CISPR 11
Annex FF (informative) - Notes on using a saline or water
bath for EMI testing
Bibliography
IEC 60601-2-62:2013 applies to the basic safety and essential performance of HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. This International Standard adds or replaces clauses listed in the IEC 60601-1 that are specific for HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. If a clause or subclause is specifically intended to be applicable to such equipment only, or to related systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to individual equipment and to systems, as relevant. Hazards inherent in the intended physiological function of the equipment or systems within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. This standard can also be applied to
- therapeutic equipment for thrombolysis through exposure to high-intensity therapeutic ultrasound;
- therapeutic equipment for the treatment of occluding feeding vessels through exposure to high-intensity focused ultrasound;
- and equipment intended to be used for relieving cancer pain due to bone metastases.
This particular standard does not apply to
- Ultrasound Equipment intended to be used for physiotherapy (use IEC 60601-2-5 and IEC 61689);
- Ultrasound Equipment intended to be used for lithotripsy (use IEC 60601-2-36);
- Ultrasound Equipment intended to be used for dedicated hyperthermia devices; and
- Ultrasound Equipment intended to be used for phacoemulsification.
| Committee |
TC 62/SC 62D
|
| DevelopmentNote |
Stability date: 2017. (07/2013)
|
| DocumentType |
Standard
|
| Pages |
131
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Standards | Relationship |
| AS/NZS IEC 60601.2.62:2022 | Identical |
| NF EN 60601-2-62 : 2015 | Identical |
| NBN EN 60601-2-62 : 2015 | Identical |
| NEN EN IEC 60601-2-62 : 2015 | Identical |
| PN EN 60601-2-62 : 2015 | Identical |
| VDE 0750-2-62:2016-04 | Identical |
| DIN EN 60601-2-62:2016-04 | Identical |
| BS EN 60601-2-62:2015 | Identical |
| CEI EN 60601-2-62 : 2016 | Identical |
| EN 60601-2-62:2015 | Identical |
| UNE-EN 60601-2-62:2015 | Identical |