Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

IEC 60708:2005

Current

Current

The latest, up-to-date edition.

Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

24-06-2005

$448.14
Including GST where applicable
Summarise this standard

FOREWORD
1 Scope
2 Normative references
3 Quality assurance
4 Cable construction
  4.1 Conductor
       4.1.1 Conductor material
       4.1.2 Type of conductor
       4.1.3 Conductor-finish
       4.1.4 Continuity of conductor
  4.2 Insulation
       4.2.1 Insulation material
       4.2.2 Insulation thickness
       4.2.3 Colour of insulated conductor
  4.3 Cabling element
  4.4 Stranding
  4.5 Colour code
       4.5.1 General
       4.5.2 Sub-units, units and cables up to and including
              100 pairs or 100 quads
       4.5.3 Cables of more than 100 pairs or 100 quads
  4.6 Spare pairs or quads
  4.7 Filling
  4.8 Core protection
  4.9 Sheath
       4.9.1 Sheath material
       4.9.2 Application of the sheath
  4.10 Cable protection
  4.11 Finished cable
       4.11.1 Overall diameter
       4.11.2 Sheath marking
       4.11.3 Sealing of ends
  4.12 Delivery
5 Mechanical requirements
  5.1 Conductor
  5.2 Insulation
  5.3 Sheath
       5.3.1 Tensile strength and elongation
       5.3.2 Adhesion of aluminium tape to the polyethylene
       5.3.3 Adhesion of aluminium tape at the overlap
  5.4 Finished cable
       5.4.1 Sheath integrity
       5.4.2 Resistance to water penetration
       5.4.3 Cable drip
6 Thermal stability and environmental requirements
  6.1 Insulation
       6.1.1 Thermal oxidative stability (OIT-test)
       6.1.2 Shrinkage
       6.1.3 Wrapping test of insulation after thermal aging
       6.1.4 Bending test at low temperature
  6.2 Sheath
       6.2.1 Elongation at break after ageing
       6.2.2 Resistance to weathering
       6.2.3 Resistance to environmental stress cracking
7 Electrical requirements
  7.1 General
  7.2 Electrical resistance of conductor
  7.3 Electrical resistance unbalance
  7.4 Dielectric strength
  7.5 Insulation resistance
  7.6 Mutual capacitance
  7.7 Capacitance unbalance
  7.8 Transmission characteristics (when used for digital
       communication)
       7.8.1 Attenuation
       7.8.2 Near End Crosstalk (NEXT)
       7.8.3 Equal Level Far-end Crosstalk (ELFEXT)
       7.8.4 Power sum (PS) of crosstalk loss
       7.8.5 Characteristic impedance
       7.8.6 Velocity of propagation
Annex A (normative) Colour code: 10 pair or 5 quad count
Annex B (normative) Colour code: sub-unit identification for
                    50 pair (25 quad) and 100 pair (50 quad)
                    cables or units, using 10 pair or 5 quad
                    count
Annex C (normative) Colour code: 25 pair count
Annex D (normative) Colour code: unit identification for
                    50 pair or quad and 100 pair or quad
                    cables or units, using 25 pair or quad
                    count
Annex E (normative) Colour code: 25 quad count
Annex F (normative) Colour code: unit identification for
                    cables with more than 100 pairs, 25 pair
                    count
Annex G (normative) Colour code: unit identification for
                    cables with more than 100 pairs or 50 quads,
                    using 10 pair or 5 quad count or 25 quad
                    count

IEC 60708:2005 is intended to define polyolefin insulated cables for insertion into local outdoor networks. Is applicable to polyolefin insulated and moisture barrier polyolefin sheathed telephone cables, filled or unfilled with copper conductors, includes general design details and requirements for dimensions and other constructional details as well as mechanical, electrical and environmental characteristics for all types of low-frequency cables with polyolefin insulation (solid or cellular), filled or unfilled, and moisture barrier polyolefin sheath (with integral suspension strand). The contents of the corrigendum of August 2016 have been included in this copy.

Committee
TC 46/SC 46C
DevelopmentNote
Supersedes IEC 60708-1. (06/2005) Stability Date: 2020. A Bilingual edition has been published on 08/04/2014. (04/2014)
DocumentType
Standard
Pages
26
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
NF EN 60708 : 2006 Identical
NEN EN IEC 60708 : 2005 C1 2016 Identical
I.S. EN 60708:2005 Identical
PN EN 60708 : 2006 AC 2017 Identical
BS EN 60708:2005 Identical
CEI EN 60708 : 2006 Identical
DIN EN 60708:2006-04 Identical
I.S. EN 60708:2005 Equivalent
UNE-EN 60708:2010 Identical
UNE-EN 60708:2005 Identical

$448.14
Including GST where applicable