Customer Support: 131 242

Your region & currency

Australia English(AU)

Pricing in AUD $

Local sites

  • Shopping Cart
    There are no items in your cart

We noticed you are browsing from United States. Switch to our United States site for local pricing in USD.

Dismiss alert
Wiring Rules bundle. AS/NZS 3000 + 3008.1.1 with 10% off already included. Shop Now

IEC 61482-2:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Live working - Protective clothing against the thermal hazards of an electric arc - Part 2: Requirements

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

20-04-2009

Superseded date

12-09-2022

$341.44
Including GST where applicable
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols and units
4 Requirements
5 Tests
6 Conformity assessment of protective clothing having
  completed the production phase
7 Modifications
Annex A (normative) - Marking and instructions for use
Annex B (normative) - Type tests
Annex C (normative) - Classification of defects
Annex D (informative) - Rationale for the classification of defects
Bibliography

IEC 61482-2:2009 is applicable to protective clothing used in work if there is an electric arc hazard. Specifies requirements and test methods applicable to materials and garments for protective clothing for electrical workers against the thermal hazards of an electric arc based on:
- relevant general properties of the textiles, tested with selected textile test methods, and
- arc thermal resistance properties, such as:
a) the arc rating of materials (ATPV or EBT50), when tested with an open electric arc under defined laboratory conditions according to IEC 61482-1-1, or
b) the arc protection class of materials and garments (Class 1 or Class 2), when tested with a directed and constrained electric arc under defined laboratory conditions according to IEC 61482-1-2.
Requirements of this standard do not address electric shock hazards. The present standard is applicable in combination with standards covering such hazards.

Committee
TC 78
DevelopmentNote
Stability Date: 2020. (05/2018)
DocumentType
Standard
Pages
44
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
NBR IEC 61482-2 : 2016 Identical
NF EN 61482-2 : 2016 PR Identical

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
$341.44