IEC 62271-105:2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

27-09-2012

Superseded date

31-12-2021

$714.89
Including GST where applicable
Summarise this standard

FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide for the selection of switch-fuse combinations
9 Information to be given with enquiries, tenders
   and orders
10 Transport, storage, installation, operation and
   maintenance
11 Safety
12 Influence of the product on the environment
Annex A (informative) - Example of the coordination
        of fuses, switch and transformer
Annex B (normative) - Procedure for determining
        transfer current
Annex C (normative) - Tolerances on test quantities
        for type tests
Bibliography

IEC 62271-105:2012 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of
- breaking, at the rated recovery voltage, any current up to and including the rated short-circuit breaking current;
- making, at the rated voltage, circuits to which the rated short-circuit breaking current applies.
It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporating single capacitor bank switches. This second edition cancels and replaces the first edition of IEC 62271-105, published in 2002, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- implementation of figures at the place where they are cited first;
- renumbering of tables;
- addition of some of the proposals from IEC paper 17A/852/INF;
- addition of missing subclauses of IEC 62271-1;
- implementation of 6.105 "Extension of validity of type tests" and consequently removing of the relevant parts in the different existing clauses;
- change of 7th paragraph of 6.101.4 as there is now a definition of NSDD given in 3.7.4 of IEC 62271-1:2007. Harmonization with IEC 62271-107;
- some referenced clauses in other standards like IEC 60282-1 were changed and therefore changed the editions under 1.2 to the ones referred to;
- addition of a new Annex C defining tolerances.

This publication is to be read in conjunction with IEC 62271-1:2007.

Committee
TC 17/SC 17A
DevelopmentNote
Supersedes IEC 60420. (08/2002) To be read in conjunction with IEC 62271-1. (09/2012) Stability Date: 2020. (11/2017)