IEC TR 62271-308:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

High-voltage switchgear and controlgear - Part 308: Guide for asymmetrical short-circuit breaking test duty T100a

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

09-08-2002

Superseded date

21-04-2008

$629.53
Including GST where applicable

FOREWORD
1 General
   1.1 Scope
   1.2 Reference documents
2 Definitions
3 Ratings
4 Test procedure
   4.1 Demonstration of arcing times during three-phase
        tests for test-duty T100a
   4.2 Demonstration of arcing times during single-phase
        tests in substitution of three-phase conditions in
        a non-solidly earthed neutral system (first
        pole-to-clear factor 1,5) for test-duty T100a
   4.3 Demonstration of arcing times during single-phase
        tests in substitution of three-phase conditions in a
        solidly earthed neutral system (first pole-to-clear
        factor 1,3) for test-duty T100a
   4.4 DC component of short-circuit breaking current
   4.5 Test-duty T100a
5 Asymmetry criteria
   5.1 Direct tests
   5.2 Synthetic tests
   5.3 Adjustment measures
Annex A Calculation of the TRV parameters during asymmetrical
        fault condition (T100a)
Annex B Table B.1 - Tolerances on test quantities for type tests
Annex C Alternative to C.2.5 of IEC 62271-100
Annex D Examples for the application of the asymmetry criteria
        during asymmetrical test duty
Annex E Updated information regarding item g) of I.2.1 of
        IEC 62271-100
Figures
Tables

This technical report contains information and test procedures for type testing of circuit-breakers relevant to short-circuit breaking performance during asymmetrical test duty (T100a) as required by IEC 62271-100.This technical report covers all possible testing cases, i.e. single-phase, three-phase, direct tests, synthetic tests, first pole-to-clear factors 1,3 and 1,5.

DocumentType
Technical Report
Pages
89
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
PD IEC/TR 62271-308:2002 Identical
NEN NPR IEC/TR 62271-308 : 2002 Identical
AS 62271.308-2005 Identical

IEC TR 62271-306:2012 High-voltage switchgear and controlgear - Part 306: Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit-breakers

IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC 60427:2000 Synthetic testing of high-voltage alternating current circuit-breakers

$629.53
Including GST where applicable