NF EN 60352-7 : 2003

Current

Current

The latest, up-to-date edition.

SOLDERLESS CONNECTIONS - PART 7: SPRING CLAMP CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE

Published date

12-01-2013

Sorry this product is not available in your region.

Introduction
1 Scope and object
2 Normative references
3 Definitions
4 Requirements
  4.1 Workmanship
  4.2 Tools
  4.3 Spring-clamp terminations
  4.4 Design features
  4.5 Wires
  4.6 Spring-clamp connections
5 Tests
  5.1 Testing
  5.2 Test methods and test requirements
  5.3 Test schedules
6 Practical guidance
  6.1 Current-carrying capacity
  6.2 Tool information
  6.3 Termination information
  6.4 Wire information
  6.5 Connection information
Figures
Tables
Annex ZA (normative) - Normative references to international
                       publications with their corresponding
                       European publications

Applies to spring-clamp connections made with stripped wire without further preparation: - solid conductors of 0.32 mm to 3.7 mm nominal diameter (0.08 mm[2] to 10 mm[2] cross-section), or - stranded conductors of 0.08 mm[2] to 10 mm[2] cross-section, or - flexible conductors of 0.08 mm[2] to 10 mm[2] cross-section.

DevelopmentNote
Indice de Classement: C93-027 PR NF EN 60352-7 October 2000. (06/2003)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

Standards Relationship
BS EN 60352-7:2002 Identical
DIN EN 60352-7:2003-07 Identical
I.S. EN 60352-7:2002 Identical
EN 60352-7:2002 Identical
UNE-EN 60352-7:2004 Identical
IEC 60352-7:2002 Identical

NF EN 50521 : 2009 AMD 1 2012 CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS

Sorry this product is not available in your region.