NFC 27 218 : 1988

Current

Current

The latest, up-to-date edition.

FLUIDS FOR ELECTROTECHNICAL APPLICATIONS - METHODS FOR THE DETERMINATION OF THE LIGHTING IMPULSE BREAKDOWN-VOLTAGE OF INSULATING LIQUIDS

Published date

12-01-2013

Sorry this product is not available in your region.

Describes two test methods, A and B, for assessing the electrical strength of insulating liquids in a divergent field when subjected to standard lightning impulses. Method A is based on a step procedure intended to provide an estimate of impulse breakdown voltage under specific conditions. Method B is a statistical test designed to check a hypothesis about the impulse breakdown probability of an insulating liquid at a given voltage level.

DevelopmentNote
Indice de Classement: C27-218 (01/2002)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

Standards Relationship
IEC 60897:1987 Identical