Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

PD IEC/TR 62296:2009

Current

Current

The latest, up-to-date edition.

Considerations of unaddressed safety aspects in the second edition of IEC 60601-1 and proposals for new requirements

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

22-01-2009

$797.50
Including GST where applicable

FOREWORD
INTRODUCTION
1 Scope and object
  1.1 Scope
  1.2 Object
2 Recommendations
  2.1 Summary of all recommendations prepared by SC 62A/WG 14
  2.2 Recommendation sheets
      2.2.1 Separation: Reliability of component impedance
      2.2.2 Separation: Non-complying creepage distance and
             air clearances
      2.2.3 Mains supply transformers: Overload test
      2.2.4 Mains supply transformers: Short circuit and
             overload tests
      2.2.5 Creepage distance and air clearances: Values
      2.2.6 Dielectric strength
      2.2.7 Failure of components: Evidence of reliability
      2.2.8 ENCLOSURES and protective covers
      2.2.9 INTERNALLY POWERED EQUIPMENT: 110% of the maximum
             supply voltage
      2.2.10 Creepage distances and air clearances: Values
             under 1 mm
      2.2.11 Separation: Secondary circuit impedance limit
             LEAKAGE CURRENT
      2.2.12 ENCLOSURES and PROTECTIVE COVERS:
             Lampholder/switching device
      2.2.13 Fixing, prevention of maladjustment: Torque test
      2.2.14 Batteries not intended to be changed by OPERATOR:
             Lithium batteries
      2.2.15 Excessive temperatures: Ambient temperatures
      2.2.16 Continuous LEAKAGE CURRENTS: Different SUPPLY MAINS
      2.2.17 ENCLOSURE and protective covers: EQUIPMENT in
             ambulances
      2.2.18 Dielectric strength: Voltages appearing from
             external sources
      2.2.19 Testing switch mode power supply units (SMPSU)
      2.2.20 Failure of an electrical component: Time periodicity
             for detection
      2.2.21 Environmental conditions: Compliance paragraph
      2.2.22 Limitation of voltage and/or energy: Capacitance
      2.2.23 LEAKAGE CURRENTS: Presence of 45 k ohms resistor in
             Figure 21
      2.2.24 Humidity preconditioning treatment: Exception
             from requirement
      2.2.25 Dielectric strength: EQUIPMENT containing
             floating circuits
      2.2.26 General requirements for tests: Measurement
             uncertainty
      2.2.27 CREEPAGE DISTANCES and AIR CLEARANCES:
             Interpolated values
      2.2.28 Overheating: Change of load resistance
      2.2.29 Mains operated EQUIPMENT with additional power
             source: Integrity of external protective earth
      2.2.30 Rechargeable batteries: No OPERATOR/USER maintenance
      2.2.31 Isolation from the SUPPLY MAINS: Symbol for single
             pole switch
      2.2.32 Sequence of testing: Clause 52 before Clause 19
      2.2.33 SINGLE FAULT CONDITION: ENCLOSURE LEAKAGE CURRENT
             from INTERNALLY POWERED EQUIPMENT
      2.2.34 Marking on the outside of EQUIPMENT: Type and
             rating of fuses
      2.2.35 Excessive temperatures: APPLIED PARTS not intended
             to supply heat
      2.2.36 Mains supply transformers: Use of PTCs as
             protective devices
      2.2.37 Components and general assembly: Reliability of
             components
      2.2.38 Definition of APPLIED PART: EQUIPMENT worn by
             PATIENTS
      2.2.39 Construction: Triple insulated winding wire
      2.2.40 CREEPAGE DISTANCES and AIR CLEARANCES:
             Dielectric strength test versus CREEPAGE
             DISTANCES and AIR CLEARANCES
      2.2.41 CREEPAGE DISTANCES and AIR CLEARANCES:
             Dielectric strength test versus CREEPAGE
             DISTANCES and AIR CLEARANCES - POWER SUPPLY CORDS
      2.2.42 ACCOMPANYING DOCUMENTS: on CD-ROM or electronic
             file format
      2.2.43 INTERNAL ELECTRICAL POWER SOURCE: Requirements
             for lithium batteries
      2.2.44 Dielectric strength: Differences between B-d and B-e
      2.2.45 Excessive temperatures: Thermocouple instead of
             resistance method
      2.2.46 Mains fuses and OVER-CURRENT RELEASEs: Fuses in
             CLASS II EQUIPMENT
      2.2.47 Plug in power supply
      2.2.48 Connecting cords between EQUIPMENT parts: Other
             applications
      2.2.49 MULTIPLE PORTABLE SOCKET-OUTLET
      2.2.50 Separation, DEFIBRILLATION-PROOF APPLIED PART:
             multiple APPLIED PARTS
      2.2.51 Separation, APPLIED PART: Hand held flexible shafts
      2.2.52 Protective earthing: No-load voltage of 6 V maximum
      2.2.53 Foot-operated control devices: Protection against
             entry of liquids
      2.2.54 Mains supply transformers
      2.2.55 Dielectric strength: Reliability of components to
             bridge A-a[2] and B-a
      2.2.56 Dielectric strength: A-e in switch mode power
             supply units (SMPSU)
      2.2.57 Dielectric strength: Connection of 12 V dc negative
             side to ENCLOSURE
      2.2.58 Dielectric strength: Voltages appearing on SIP/SOP
      2.2.59 APPLIED PART: EQUIPMENT without APPLIED PART
      2.2.60 Scope: Other than MEDICAL ELECTRICAL EQUIPMENT in
             contact with the body of a person
      2.2.61 Markings: AC symbol
      2.2.62 Interruption of power supply: Characteristics of
             interruption
      2.2.63 Reference voltage: Different reference voltages in
             the same circuit
Bibliography
Index of Terms

Provides a series of recommendations developed by an expert working group of IEC subcommittee 62A in response to questions of interpretation of the second edition of IEC 60601-1.

Committee
CH/62/1
DevelopmentNote
Supersedes 02/562754 DC (09/2003)
DocumentType
Standard
Pages
82
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC/TR 62296:2009(E) contains a series of recommendations developed by an expert working group of IEC subcommittee 62A in response to questions of interpretation of the second edition of IEC 60601-1. IEC/TR 62296:2009(E) is primarily intended to be used by:
- manufacturers of medical electrical equipment;
- test houses and others responsible for assessment of compliance with IEC 60601-1:1988, and
- those developing subsequent editions of IEC 60601-1.
The recommendations in the first edition of IEC/TR 62296 were considered in preparing the third edition of IEC 60601-1. As the third edition of IEC 60601-1 has been published, some of the recommendations in the second edition of IEC/TR 62296 have been changed to align with requirements in IEC 60601-1:2005. Seven additional recommendations have been developed by IEC/SC 62A/WG 14 and are included in this edition of IEC/TR 62296. They are recommendations 57 through 63. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. This edition includes seven new recommendations: Recommendations 57 through 63. As the third edition of IEC 60601-1 has been published, some of the recommendations in this edition have been changed to align with requirements in IEC 60601-1:2005.

Standards Relationship
IEC TR 62296:2009 Identical

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
IEC 60320-1:2015 Appliance couplers for household and similar general purposes - Part 1: General requirements
ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60364-7-710:2002 Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV Plugs and socket-outlets for household and similar purposes - Part1: General requirements
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links
IEC 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC TR 60930:2008 Guidelines for administrative, medical and nursing staff concerned with the safe use of medical electrical equipment and medical electrical systems
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 60601-1-1:2000 Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests

$797.50
Including GST where applicable