Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

PREN 15058 : DRAFT 2014

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF CARBON MONOXIDE - STANDARD REFERENCE METHOD: NON-DISPERSIVE INFRARED SPECTROMETRY

Published date

03-11-2014

Superseded date

01-01-2017

Superseded by

EN 15058:2017

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Description of the measuring system
6 Performance characteristics of the SRM
7 Suitability of the measuring system for the
   measurement task
8 Field operation
9 Ongoing quality control
10 Expression of results
11 Equivalency of an alternative method
12 Test report
Annex A (informative) - Procedure of correction of
        data from drift effect
Annex B (informative) - Schematics of non-dispersive
        infrared spectrometer
Annex C (informative) - Example of assessment of
        compliance of non-dispersive infrared method
        for CO with requirements on emission measurements
Annex D (informative) - Calculation of the uncertainty
        associated with a concentration expressed
        on dry gas and at an oxygen reference concentration
Annex E (informative) - Evaluation of the method in the field
Annex F (informative) - Significant technical changes
Bibliography

Defines the standard reference method (SRM) based on the infra-red (IR) absorption principle.

Committee
TC 264
DocumentType
Draft
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
14/30293554 DC : 0 Identical

VDI 3476 Blatt 1:2015-06 Waste gas cleaning - Methods of catalytic waste gas cleaning - Fundamentals
VDI 3899 Blatt 1:2016-05 Emission control - Landfill gas - Utilisation and treatment of landfill gas
VDI 2578:2017-05 Emission control - Glassworks
15/30318313 DC : 0 BS EN 15267-4 - AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 4: PERFORMANCE CRITERIA AND TEST PROCEDURES FOR AUTOMATED MEASURING SYSTEMS FOR PERIODIC MEASUREMENTS OF EMISSIONS FROM STATIONARY SOURCE

EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
PREN 14790 : DRAFT 2014 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
ISO/IEC Guide 99:2007 International vocabulary of metrology — Basic and general concepts and associated terms (VIM)
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
PREN 14793 : DRAFT 2014 STATIONARY SOURCE EMISSIONS - DEMONSTRATION OF EQUIVALENCE OF AN ALTERNATIVE METHOD WITH A REFERENCE METHOD
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Sorry this product is not available in your region.