UNE 211632-4A:2017

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath.

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian

Published date

04-10-2017

Superseded date

29-03-2023

Superseded by

UNE 211632-4A:2023

$133.21
Including GST where applicable

This standard specifies the characteristics, design, manufacture, delivery and testing to be complied by the HV unipolar cables (and cable system) of rated voltage 26/45 (52) kV, 36/66 (72.5) kV, 64/110 (123) kV, 76/132 (145) kV and 87/150 (170) kV with cross-linked polyethylene dry insulation (XLPE) and polyolefin or high density polyethylene sheath.

Committee
CTN 211/SC 20A
DocumentType
Standard
Pages
18
PublisherName
Asociación Española de Normalización
Status
Superseded
SupersededBy
Supersedes

EN 60811-409:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths
HD 632 S1:1998 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
EN 60811-503:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths
EN 60811-505:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
EN 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 50575:2014/A1:2016 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
EN 60811-502:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations
IEC 60230:1966 Impulse tests on cables and their accessories
EN 60754-1:2014 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
IEC 60229:2007 Electric cables - Tests on extruded oversheaths with a special protective function
EN 60885-3:2015 Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
EN 60811-507:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
EN 60811-203:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions
EN 60811-402:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

$133.21