Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

VDE 0411-114 : 1996

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PARTICULAR REQUIREMENTS FOR LABORATORY EQUIPMENT FOR MIXING AND STIRRING

Published date

12-01-2013

Superseded date

01-07-2004

Superseded by

VDE 0411-2-051 : 2016

Sorry this product is not available in your region.

Vorwort
1 Anwendungsbereich und Zweck
2 Normative Verweisungen
3 Begriffe
4 Prüfungen
5 Aufschriften und Dokumentation
6 Schutz gegen gefährliche Körperströme
7 Schutz gegen mechanische Gefährdung
8 Mechanische Festigkeit gegen Fallen, Erschütterung
   und Schlag
9 Temperaturgrenzen und Schutz gegen die Ausbreitung
   von Feuer
10 Wärmebeständigkeit
11 Schutz vor Gefahren durch Fluide
12 Schutz gegen Strahlung, einschliesslich
   Laserstrahlung und gegen Schall- und
   Ultraschalldruck
13 Schutz gegen freigesetzte Gase, Explosion und
   Implosion
14 Bauelemente
15 Schutz durch Sicherheitsverriegelung
16 Messkreise
Anhänge A bis M
Anhang ZA (normativ) Normative Verweisungen auf
          internationale Publikationen mit ihren
          entsprechenden europäischen Publikationen

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy

Standards Relationship
IEC 61010-2-051:2015 Identical
EN 61010-2-051:2015 Identical
DIN EN 61010-2-051 : 2016 Identical
DIN EN 61010-2-051:1996-03 Identical

DIN EN 61010-2-031 : 1995 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 2-031: PARTICULAR REQUIREMENTS FOR HAND-HELD PROBE ASSEMBLIES FOR ELECTRICAL MEASUREMENT AND TEST
VDE 0411-2-031 : 1995 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PARTICULAR REQUIREMENTS FOR HAND-HELD PROBE ASSEMBLIES FOR ELECTRICAL MEASUREMENT AND TEST
VDE 0411-2-042 : 1997 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-042: PARTICULAR REQUIREMENTS FOR AUTOCLAVES AND STERILIZERS USING TOXIC GAS FOR THE TREATMENT OF MEDICAL MATERIALS, AND FOR LABORATORY PROCESSES
VDE 0411-2-041 : 1996 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 2-041: PARTICULAR REQUIREMENTS FOR AUTOCLAVES USING STEAM FOR THE TREATMENT OF MEDICAL MATERIALS AND FOR LABORATORY PROCESSES
DIN EN 61010-2-042 : 1997 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-042: PARTICULAR REQUIREMENTS FOR AUTOCLAVES AND STERILIZERS USING TOXIC GAS FOR THE TREATMENT OF MEDICAL MATERIALS, AND FOR LABORATORY PROCESSES
DIN EN 61010-2-041 : 1996 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 2-041: PARTICULAR REQUIREMENTS FOR AUTOCLAVES USING STEAM FOR THE TREATMENT OF MEDICAL MATERIALS AND FOR LABORATORY PROCESSES

VDE 0411-2-010 : 2015 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 2-010: PARTICULAR REQUIREMENTS FOR LABORATORY EQUIPMENT FOR THE HEATING OF MATERIALS (IEC 61010-2-010:2014)
DIN EN 61010-2-010 : 2015 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 2-010: PARTICULAR REQUIREMENTS FOR LABORATORY EQUIPMENT FOR THE HEATING OF MATERIALS (IEC 61010-2-010:2014)
EN 61010-2-010:2014 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of Materials
IEC 61010-2-010:2014 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of materials

Sorry this product is not available in your region.