• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 1012.13-1992

Superseded

Superseded

View Superseded by

Methods of testing concrete Determination of the drying shrinkage of concrete for samples prepared in the field or in the laboratory

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

01-01-1992

Superseded date

05-23-2024

US$57.21
Excluding Tax where applicable
Summarise this standard

1 - AS 1012.13-1992 METHODS OF TESTING CONCRETE - DETERMINATION OF THE DRYING SHRINKAGE OF CONCRETE FOR SAMPLES PREPARED IN THE
1 - PREFACE
1 - CONTENTS
2 - METHOD
2 - 1 SCOPE
2 - 2 REFERENCED DOCUMENTS
2 - 3 DEFINITIONS
2 - 3.1 Standard moist curing conditions
2 - 3.2 Preparing laboratory
2 - 3.3 Measuring laboratory
2 - 3.4 Micrometer
2 - 4 PRINCIPLE
2 - 5 APPARATUS
2 - 5.1 General
2 - 5.2 Drying room
3 - 5.3 Moulds
3 - 5.4 Gauge studs
3 - 5.5 Length gauge
3 - 5.6 Tamping bar (hand compaction)
5 - 5.7 Vibrator
5 - 5.8 Mallet
5 - 5.9 Length comparator
5 - 6 SAMPLING AND TEST SPECIMENS
5 - 6.1 Sampling
6 - 6.2 Preparation of test specimens
6 - 7 PROCEDURE
6 - 7.1 Measurement of consistence
6 - 7.2 Moulding specimens
7 - 7.3 Curing of specimens
8 - 7.4 Drying and measurement of specimens
9 - 8 CALCULATION AND EXPRESSION OF RESULTS
9 - 9 PRECISION FOR LABORATORY-PREPARED SPECIMENS
9 - 10 RECORDS
10 - 11 REPORT
11 - APPENDIX A - A SUITABLE HORIZONTAL LENGTH COMPARATOR
11 - A1 GENERAL
11 - A2 COMPARATOR FRAME
11 - A3 MICROMETER

Sets out a method for determining the drying shrinkage of concrete. Generally similar to the 1970 edition, except that the differences between field and laboratory prepared specimens has been emphasized.

Committee
BD-042
DocumentType
Standard
ISBN
0 7262 7274 4
Pages
11
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out a method for preparing and curing of concrete shrinkage specimens, and for determining the length changes of these specimens due to drying in air. It provides for testing of specimens prepared in the laboratory or in the field, in which the nominal size of aggregate in the concrete, in accordance with AS 2758.1, does not exceed 40 mm. The precision statement in Clause 9 does not apply to specimens which have had non-standard initial curing (normally field-prepared specimens). In addition this Standard requires that field-prepared specimens are marked, recorded and reported as such.NOTES:This test method is not always suitable for very low slump concrete (less than 20 mm), primarily due to the difficulties in obtaining adequate compaction. Provided adequate compaction is obtained, the method is applicable. The method is specifically designed for measurement of drying shrinkage of concrete, but it is capable of adaptation for measurement of length changes of specimens subjected to a variety of environmental conditions.

First published as AS 1012.13-1970.
Second edition 1992.

⚠

A newer version of this standard is available.

View Current Edition View Current Edition