• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 1684.4-2010

Superseded

Superseded

View Superseded by

Residential timber-framed construction Simplified - Non-Cyclonic Areas

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

06-22-2010

Superseded date

04-01-2026

Superseded by

AS 1684.4:2024

US$88.13
Excluding Tax where applicable
Summarise this standard

AS 1684.4 2010 specifies requirements for the building industry with procedures that can be used to determine building practice, to design or check construction details, and to determine member sizes, and bracing and fixing requirements for timber-framed construction in non-cyclonic wind classifications N1 and N2. Also referred to as the timber framing code.

Committee
TM-002
DocumentType
Standard
ISBN
978 0 7337 9436 0
Pages
194
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard specifies requirements for building practice and for the selection, placement and fixing of the various structural elements used in the construction of timber-framed Class 1 and Class 10 Buildings as defined by the Building Code of Australia and within the limitations given in Clause 1.4. The provisions of the Standard also apply to alterations and additions to these buildings.This Standard also provides building practice and procedures that assist in the correct specification and determination of timber members, bracing and connections, thereby minimizing the risk of creating an environment that may adversely affect the ultimate performance of the structure.This Standard may also be applicable to the design and construction of other classes of buildings where the design criteria, loadings and other parameters applicable to those classes of building are within the limitations of this Standard.NOTES:1 See AS 1684.1 for details of design criteria, loadings and other parameters.2 Whilst this Standard may be used to design Class 10 buildings, less conservative levels of design for this building class may be permitted by building regulations and other Australian Standards.3 Advisory information for the construction and specifications of timber stairs, handrails and balustrades, is provided in the FWPA’s publication (see the Bibliography).Member Span Tables are given in Appendix A.

First published as AS O56-1946.
Second edition 1948.
Revised and redesignated as AS CA38-1971.
Revised and redesignated as AS 1684-1975.
Third edition 1992.
Revised and redesignated in part as AS 1684.4-1999.
Third edition 2010.
Reissued incorporating Amendment No. 1 (June 2012).

⚠

A newer version of this standard is available.