AS 1905.1-2005
Superseded
View Superseded by
Components for the protection of openings in fire-resistant walls Fire-resistant doorsets
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
09-09-2005
07-25-2024
Specifies requirements for design, construction and installation of doorsets used to protect openings in fire-resistant walls and partitions. Compliance is based on prototype testing in accordance with AS1530.4. Labelling requirements are included.
| Committee |
FP-019
|
| DocumentType |
Standard
|
| ISBN |
0 7337 6846 6
|
| Pages |
41
|
| PublisherName |
Standards Australia
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes | |
| UnderRevision |
This Standard specifies requirements for the construction and installation of fire-resistant doorsets used to protect openings in walls and partitions that are required to resist the passage of fire. It also applies to transom panels over doors, where the panels are contained within the doorframe and form part of the doorset.This Standard does not apply to lift-landing doors.NOTES:1 Where it is intended to install the fire-resistant doorset in high-traffic areas, it is recommended that it be tested in accordance with AppendixA prior to fire testing and that it complies with the requirements set out therein.2 Durability designations for locksets and methods for their cycle testing, for minimal, moderate and high frequency usage, are given in AS4145.2.3 Manufacturers of fire-resistant doorsets are strongly encouraged to implement quality control systems in accordance with AS/NZSISO9001. Guidance on the introduction and maintenance of suitable quality systems is given in AS/NZSISO9000 and AS/NZSISO9004.4 Guidance on information that should be supplied with an enquiry or order is given in AppendixB.5 Requirements governing lift-landing doors are given in AS1735.11.6 A panel above a doorset, which is not contained within the doorframe, is considered as being part of the wall and is therefore subject to the structural adequacy, integrity and insulation requirements set out in the Building Code of Australia (BCA).7 A transom or mullion within a doorframe may be permanently fixed to the side members of the frame or may be removable by means of mechanical fixing.8 A smoke control system (or other external environmental conditions) can impose loads greater than 5N on the strike. In such circumstances, a substantially greater resistance force may be required of the strike to ensure the door remains in the latched position during a fire emergency.9 This Standard does not include the evaluation of smoke leakage under ambient and medium temperature exposures. Other Standards such as AS/NZS1530.7 may be used for evaluating the potential for smoke spread.
First published in Australia as AS CA57.1-1972.
Revised and redesignated AS 1905.1-1976.
Fourth edition 1990.
First published in New Zealand as part of NZS 1188:1954.
Revised and redesignated in part as NZS 4232.1:1988.
AS 1905.1-1990 and NZS 4232.1:1988, jointly revised, amalgamated and designated AS/NZS 1905.1:1997.
AS/NZS 1905.1:1997 revised and redesignated as AS 1905.1-2005.
A newer version of this standard is available.
View Current Edition