1 - AS 2118.1-1999 AUTOMATIC FIRE SPRINKLER SYSTEMS - GENERAL REQUIREMENTS
4 - PREFACE
5 - CONTENTS
8 - FOREWORD
9 - SECTION 1 SCOPE AND GENERAL
9 - 1.1 SCOPE
9 - 1.2 OBJECTIVE
9 - 1.3 APPLICATION
9 - 1.4 NEW DESIGNS AND INNOVATIONS
9 - 1.5 REFERENCED DOCUMENTS
9 - 1.6 DEFINITIONS
9 - 1.6.1 Alarm signalling equipment (ASE)
9 - 1.6.2 Alarm valve
9 - 1.6.3 Assumed area of operation
10 - 1.6.4 Building owner
10 - 1.6.5 Compartment
10 - 1.6.6 Effective height
10 - 1.6.7 Encapsulated
10 - 1.6.8 Fire and draught stop
10 - 1.6.9 Installation
10 - 1.6.10 Listed
10 - 1.6.11 Monitoring service
11 - 1.6.12 Multiple controls
11 - 1.6.13 Net positive suction head (NPSH)
11 - 1.6.14 Open joists and exposed common rafters
11 - 1.6.15 Post or box pallet
11 - 1.6.16 Relevant authority
11 - 1.6.17 Special sprinkler
12 - 1.6.18 Special sprinkler system
12 - 1.6.19 Sprayers
12 - 1.6.20 Sprinkler-protected area
12 - 1.6.21 Sprinkler-protected building
12 - 1.6.22 Sprinkler system
13 - 1.6.23 Standard sprinkler system
13 - 1.6.24 Standard sprinkler
15 - SECTION 2 CLASSIFICATION OF SPRINKLER SYSTEMS AND DESIGN DATA
15 - 2.1 CLASSIFICATION OF SYSTEMS
15 - 2.2 CLASSIFICATION OF OCCUPANCIES
15 - 2.3 TYPES OF SPRINKLER SYSTEMS
15 - 2.3.1 General
16 - 2.3.2 Standard sprinkler system
20 - 2.3.3 Special sprinkler systems
22 - 2.4 DESIGN DATA
23 - SECTION 3 INSTALLATION
23 - 3.1 SPRINKLER-PROTECTED BUILDINGS
23 - 3.1.1 Extent of sprinkler protection
23 - 3.1.2 Protection against exposure hazards
25 - 3.1.3 Permitted exceptions
26 - 3.2 TRANSMISSION OF ALARM SIGNAL TO FIRE BRIGADE
26 - 3.3 LOCAL ALARM
27 - 3.4 SYSTEM COMPONENT FAULT MONITORING
27 - 3.4.1 General
27 - 3.4.2 Monitoring devices
27 - 3.4.3 Systems to be monitored
27 - 3.4.4 Components to be monitored
28 - 3.4.5 Installation
29 - SECTION 4 WATER SUPPLIES
29 - 4.1 GENERAL
29 - 4.1.1 Requirements
29 - 4.1.2 Additives
29 - 4.2 ACCEPTABLE SOURCES OF SUPPLY
30 - 4.3 WATER SUPPLY GRADES
30 - 4.3.1 General
30 - 4.3.2 Grade 3 water supplies
30 - 4.3.3 Grade 2 water supplies
31 - 4.3.4 Grade 1 water supplies
41 - 4.4 CONNECTIONS TO OTHER SERVICES
41 - 4.4.1 General
42 - 4.4.2 Fire hose reel connections
42 - 4.4.3 Fire brigade booster connection
43 - 4.5 PRESSURE AND FLOW REQUIREMENTS
43 - 4.6 PRESSURE CONSIDERATIONS
43 - 4.7 MINIMUM CAPACITY OF STORED WATER SUPPLIES
43 - 4.8 PUMP SUCTION TANKS
43 - 4.8.1 General
44 - 4.8.2 Effective capacity
46 - 4.8.3 Vortex inhibitor
47 - 4.8.4 Supply from inexhaustible source
50 - 4.9 PRIVATE WATER SUPPLIES
50 - 4.9.1 General
50 - 4.9.2 Elevated private reservoirs
50 - 4.9.3 Gravity tanks
50 - 4.10 TOWN MAINS
50 - 4.10.1 Direct supply from town mains
51 - 4.10.2 Pump drawing from town mains
52 - 4.11 PUMP INSTALLATIONS
52 - 4.11.1 General requirements
52 - 4.11.2 Pump operating conditions
53 - 4.11.3 Suction piping
53 - 4.11.4 Performance requirements for pumps
53 - 4.12 PUMPSETS
58 - 4.13 PRESSURE TANKS
58 - 4.13.1 General
58 - 4.13.2 Special requirements
60 - 4.14 PROVING OF WATER SUPPLIES
62 - SECTION 5 SPACING AND LOCATION OF SPRINKLERS
62 - 5.1 STANDARD SPACING
62 - 5.2 STAGGERED SPACING
62 - 5.3 MINIMUM DISTANCE BETWEEN SPRINKLERS
62 - 5.4 LOCATION OF SPRINKLERS (OTHER THAN SIDEWALL SPRINKLERS)
62 - 5.4.1 General
62 - 5.4.2 Walls and partitions
64 - 5.4.3 Ceilings, roofs and underside of stairs
64 - 5.4.4 Beams and joists
65 - 5.4.5 Columns
65 - 5.4.6 Girders
65 - 5.4.7 Roof trusses
65 - 5.4.8 Clear space below sprinklers
67 - 5.5 SPACING AND LOCATION OF SIDEWALL SPRINKLERS
67 - 5.5.1 General
67 - 5.5.2 Maximum spacing of sidewall sprinklers
68 - 5.5.3 Distance between rows of sprinklers
68 - 5.6 LOCATIONS OR CONDITIONS INVOLVING SPECIAL CONSIDERATION (SUPPLEMENTARY PROTECTION)
68 - 5.6.1 Concealed spaces
69 - 5.6.2 Spaces under ground floors
69 - 5.6.3 Hydraulic design-Concealed spaces
70 - 5.6.4 Machinery pits and production lines
70 - 5.6.5 Hoists, lift shafts, building services shafts and enclosed chutes
70 - 5.6.6 Elevators, rope or strap races, exhaust ducts, gearing boxes and dust receivers
70 - 5.6.7 Corn, rice, provender and oil mills
71 - 5.6.8 Bins and silos
71 - 5.6.9 Escalators
71 - 5.6.10 Canopies
71 - 5.6.11 Roof overhang
71 - 5.6.12 Exterior docks and platforms
72 - 5.6.13 Covered balconies
72 - 5.6.14 Enclosed paint lines, drying ovens, drying enclosures
72 - 5.6.15 Spray booths
72 - 5.6.16 Oil and flammable liquid hazards
72 - 5.6.17 Commercial type cooking equipment and associated ventilation systems
75 - 5.6.18 Air-handling plant
75 - 5.6.19 Computer and other electronic equipment areas
75 - 5.7 OBSTRUCTIONS BELOW SPRINKLERS
75 - 5.7.1 General
75 - 5.7.2 Overhead platforms
76 - 5.7.3 Ducts and bulkheads
76 - 5.7.4 Suspended ceilings
76 - 5.7.5 Suspended open grid ceilings
76 - 5.7.6 Hoods over papermaking machines
76 - 5.7.7 Storage racks
76 - 5.7.8 Storage fixtures of solid and slatted shelved construction
77 - 5.8 FILM AND TELEVISION PRODUCTION STUDIOS
77 - 5.8.1 Overhead platforms and walkways
77 - 5.8.2 Concealed spaces and cavities
77 - 5.9 THEATRES AND MUSIC HALLS (PROTECTION ON THE STAGE SIDE OF THE PROSCENIUM WALL)
77 - 5.10 COLD STORAGE WAREHOUSE
77 - 5.10.1 General
78 - 5.10.2 Piping within the cold chamber
80 - SECTION 6 SPRINKLERS, SPRAYERS AND MULTIPLE CONTROLS
80 - 6.1 GENERAL
80 - 6.2 TYPES OF SPRINKLERS, SPRAYERS AND MULTIPLE CONTROLS
80 - 6.2.1 Standard sprinklers
80 - 6.2.2 Special sprinklers
80 - 6.2.3 Sprayers
81 - 6.2.4 Multiple controls
81 - 6.3 STANDARD SPRINKLE K FACTORS, ORIFICE AND THREAD SIZES
81 - 6.4 APPLICATION OF SPRINKLER TYPES
81 - 6.5 TEMPERATURE RATINGS
82 - 6.6 COLOUR CODING
82 - 6.7 STOCK OF REPLACEMENT SPRINKLERS
82 - 6.7.1 Special sprinklers
82 - 6.8 ANTI-CORROSION TREATMENT OF SPRINKLERS
82 - 6.9 SPRINKLER GUARDS
83 - 6.10 ESCUTCHEON PLATE ASSEMBLIES
83 - 6.11 PROTECTION AGAINST FROST
84 - SECTION 7 PIPING
84 - 7.1 PIPE AND PIPE FITTINGS
84 - 7.2 HYDRAULIC TEST PRESSURE
84 - 7.3 PIPING IN NON-SPRINKLER-PROTECTED BUILDINGS
84 - 7.4 HAZARDOUS PROCESSES AND EXPLOSION HAZARD - SPECIAL PRECAUTIONS CONCERNING PIPING AND VALVES
84 - 7.5 SLOPE OF PIPES FOR DRAINAGE
85 - 7.6 LOW LEVEL DRAINAGE
85 - 7.7 PIPE SIZES
85 - 7.8 ORIFICE PLATES
85 - 7.9 SUPPORT OF SPRINKLER PIPING
86 - SECTION 8 VALVES AND ANCILLARY EQUIPMENT
86 - 8.1 CONTROL ASSEMBLIES
86 - 8.2 STOP VALVES
86 - 8.2.1 General
86 - 8.2.2 Main stop valves
86 - 8.2.3 Stop valves controlling water supplies
87 - 8.2.4 Subsidiary stop valves
87 - 8.3 BLOCK PLAN
87 - 8.4 LOCATION PLATE
88 - 8.5 EMERGENCY INSTRUCTIONS
88 - 8.6 NON-RETURN (BACK PRESSURE) VALVES
88 - 8.7 ALARM VALVES
88 - 8.7.1 Alarm valves (wet)
88 - 8.7.2 Alarm valves (dry)
89 - 8.7.3 Composite alarm valves
89 - 8.7.4 Identification of alarm valves and alarm gongs
89 - 8.7.5 Accelerators or exhausters for alarm valves (dry system)
89 - 8.8 PRESSURE-REDUCING VALVES
89 - 8.9 DELUGE AND PRE-ACTION VALVES
89 - 8.9.1 Deluge valves
89 - 8.9.2 Pre-action valves
90 - 8.10 ALARM DEVICES
90 - 8.10.1 General
90 - 8.10.2 Prevention of false alarms
90 - 8.10.3 Local water motor alarms
90 - 8.10.4 Fire alarm signal
91 - 8.10.5 Pressure switches
91 - 8.10.6 Testing of alarm devices
91 - 8.11 REMOTE TEST VALVES
92 - 8.12 PRESSURE GAUGES
94 - SECTION 9 LIGHT HAZARD CLASS SYSTEMS
94 - 9.1 SCOPE
94 - 9.2 DESIGN DATA
94 - 9.3 WATER SUPPLY
94 - 9.3.1 Pressure and flow requirements
94 - 9.3.2 Water storage capacity
94 - 9.3.3 Additional storage capacity
94 - 9.3.4 Pump suction tanks
95 - 9.3.5 Pressure tanks
95 - 9.3.6 Pumpsets
95 - 9.3.7 Proving of water supplies
95 - 9.4 SPRINKLERS
95 - 9.4.1 Size and type
95 - 9.4.2 Maximum area coverage per sprinkler
95 - 9.4.3 Reduced coverage
96 - 9.4.4 Maximum spacing
96 - 9.4.5 Special sprinklers
96 - 9.5 PIPING
96 - 9.5.1 Pipe types
96 - 9.5.2 Pipe sizes
96 - 9.5.3 Hydraulic calculations
96 - 9.5.4 Concealed spaces
96 - 9.5.5 System drainage
97 - SECTION 10 ORDINARY HAZARD CLASS SYSTEMS
97 - 10.1 DESIGN DATA
97 - 10.2 WATER SUPPLIES
97 - 10.2.1 Pressure and flow requirements
98 - 10.2.2 Minimum capacity of water supplies
100 - 10.2.3 Pumps
100 - 10.2.4 Proving of water supplies
100 - 10.3 SPACING OF STANDARD SPRINKLERS
100 - 10.3.1 Maximum area coverage per sprinkler
101 - 10.3.2 Maximum distance between sprinklers on range pipes and between adjacent rows of sprinklers
101 - 10.3.3 Maximum distance from walls and partitions (see also Clauses 5.4.2 and 5.5)
101 - 10.4 SYSTEM COMPONENTS
101 - 10.4.1 Sprinklers
101 - 10.4.2 Piping
106 - 10.5 SYSTEM DRAINAGE
107 - SECTION 11 HIGH HAZARD CLASS SYSTEMS
107 - 11.1 DESIGN DATA
107 - 11.1.1 General
107 - 11.1.2 Process risks
107 - 11.1.3 High piled storage risks
113 - 11.1.4 Type of system
117 - 11.2 WATER SUPPLIES
117 - 11.2.1 Pressure and flow requirements
119 - 11.2.2 Minimum capacity of water supplies
121 - 11.2.3 Pumps
121 - 11.2.4 Proving of water supplies
121 - 11.3 SPACING OF STANDARD SPRINKLERS
121 - 11.3.1 Maximum area coverage per sprinkler
122 - 11.3.2 Maximum distance between sprinklers on range pipes and between adjacent rows of sprinklers
122 - 11.3.3 Maximum distance from walls and partitions
122 - 11.4 SYSTEM COMPONENTS
122 - 11.4.1 Sprinklers
122 - 11.4.2 Piping
124 - 11.5 SYSTEM DRAINAGE
132 - SECTION 12 FULL HYDRAULIC CALCULATION OF SPRINKLER SYSTEMS
132 - 12.1 GENERAL
132 - 12.2 DESIGN REQUIREMENTS FOR DENSITY OF DISCHARGE
133 - 12.3 ASSUMED AREA OF OPERATION
133 - 12.4 SPRINKLERS IN OPERATION
133 - 12.5 POSITION OF ASSUMED AREA OF OPERATION
133 - 12.5.1 Hydraulically most unfavourable area of operation
134 - 12.5.2 Hydraulically most favourable area of operation
134 - 12.6 SHAPE OF ASSUMED AREA OF OPERATION
134 - 12.6.1 Hydraulically most unfavourable area of operation
135 - 12.6.2 Hydraulically most favourable area of operation
135 - 12.7 WATER SUPPLIES
135 - 12.8 PUMPSETS
135 - 12.8.1 General
135 - 12.8.2 Maximum flow rates
136 - 12.9 CALCULATION OF PRESSURE LOSS IN PIPES
139 - 12.10 PRESSURE LOSSES
139 - 12.10.1 Fittings and valves
139 - 12.10.2 Dry pendent (or upright) sprinklers
139 - 12.11 ACCURACY OF CALCULATIONS
140 - 12.12 MINIMUM SPRINKLER DISCHARGE PRESSURE
140 - 12.13 MINIMUM PIPE SIZES
140 - 12.14 VELOCITY LIMITATION
140 - 12.15 VELOCITY PRESSURE
140 - 12.16 IDENTIFICATION OF FULLY HYDRAULICALLY CALCULATED SYSTEMS
148 - APPENDIX A -OCCUPANCY CLASSIFICATIONS
148 - A1 INTRODUCTION
148 - A2 LIGHT HAZARD OCCUPANCIES
148 - A3 ORDINARY HAZARD OCCUPANCIES
148 - A3.1 Ordinary Hazard 1 occupancies (OH 1)
149 - A3.2 Ordinary Hazard 2 occupancies (OH 2)
150 - A3.3 Ordinary Hazard 3 occupancies (OH 3)
152 - A3.4 Ordinary Hazard Special (OH Special) occupancies
152 - A4 HIGH HAZARD OCCUPANCIES
152 - A4.1 High Hazard-Process Risks
153 - A4.2 High Hazard-High-piled Storage Risks
155 - A4.3 Storage risks requiring special consideration
156 - APPENDIX B - REFERENCED DOCUMENTS
158 - APPENDIX C - ORIFICE PLATES
158 - C1 SCOPE
158 - C2 REQUIREMENTS
158 - C3 NOTES ON THE USE OF TABLES C1 AND C2
161 - APPENDIX D - PIPING INTERPRETATIONS
164 - INDEX