AS 2184-1985
Withdrawn
Low voltage switchgear and controlgear - Moulded-case circuit-breakers for rated voltages up to and including 600 V a.c. and 250 V d.c.
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
01-01-1985
06-30-2017
Deals with characteristics, design and construction, type and routine tests of single-pole and multi-pole moulded-case circuit-breakers, including those which incorporate replaceable current-limiting fuses, for interrupting ratings of 10 kA and above. It may also be used to verify the breaking capacity of moulded-case circuit-breakers within interrupting ratings of 3 kA to 10 kA, which otherwise fall within the scope of AS 3111. Additional requirements may apply to miniature overcurrent circuit-breakers in approvals regulations.
| Committee |
EL-006
|
| DocumentType |
Standard
|
| ISBN |
0 7262 3708 6
|
| Pages |
22
|
| PublisherName |
Standards Australia
|
| Status |
Withdrawn
|
| Supersedes |
This standard specifies requirements for single-pole and multipole moulded-case air-break circuit-breakers, including circuit-breakers incorporating replaceable current limiting fuses, having voltage ratings up to and including 600 V a.c. and 250 V d.c. and interrupting ratings of 10 kA or more.It does not apply to single-pole and multipole circuit-breakers intended for installation in rail or road vehicles or in aircraft.NOTES:1. Although this standard is intended to apply only to circuit-breakers having an interrupting rating of 10 kA or more, the interrupting rating tests (see Clause 8.2.9) are used to verify claimed breaking capacities between 3 kA and 10 kA of circuit-breakers falling within the scope of AS 3111.2. Additional requirements may apply to miniature over-current circuit-breakers in approvals regulations.
| AS 3111-1994 | Approval and test specification - Miniature overcurrent circuit-breakers |
| AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
| AS 2676.2-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells |
| AS 1418.14-1996 | Cranes (including hoists and winches) Requirements for cranes subject to arduous working conditions |
| AS 2676.2:2020 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings Sealed cells |
| AS 2676.1:2020 | Installation, maintenance, testing and replacement of secondary batteries in buildings Vented cells |
| AS 2467-2008 | Maintenance of electrical switchgear |
| AS 3111-1983 | Approval and test specification for miniature overcurrent circuit-breakers |
| AS 2467-1981 | Maintenance of electrical switchgear |
| AS 3111-1994 | Approval and test specification - Miniature overcurrent circuit-breakers |
| AS 2595.1-1992 | Electrical equipment for coal mines - Electrical requirements for underground mining machines and accessories - Equipment for use in hazardous areas |
| AS/NZS 3012:1995 | Electrical installations - Construction and demolition sites |
| AS 1029.2-1982 | Low voltage contactors - Semiconductor (solid state) (up to and including 1000 V a.c. and 1500 V d.c.) |
| AS 2676.1-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells |
| AS 60947.2-2005 | Low-voltage switchgear and controlgear Circuit-breakers |
| AS 4086.2-1997 | Secondary batteries for use with stand-alone power systems Installation and maintenance |