• Shopping Cart
    There are no items in your cart

AS 2224.1-2009

Withdrawn

Withdrawn

Medicine measures Glass

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-2009

Withdrawn date

01-17-2020

US$56.45
Excluding Tax where applicable

1 - AS 2224.1-2009 MEDICINE MEASURES - GLASS
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 REFERENCED DOCUMENTS
6 - 3 DEFINITIONS
6 - 3.1 Capacity at any graduation line
6 - 3.2 Permanently marked
6 - 3.3 Lead glass
6 - 4 MATERIAL
7 - 5 DESIGN AND DIMENSIONS
7 - 5.1 Design
7 - 5.2 Dimensions
7 - 6 CONSTRUCTION
7 - 6.1 General
7 - 6.2 Stability
7 - 6.3 Wall thickness
7 - 6.4 Pouring lip
7 - 6.5 Finish
8 - 7 MARKINGS
8 - 7.1 Calibration markings
8 - 7.1.1 Scale marks
8 - 7.1.2 Graduation lines
8 - 7.1.3 Figures
8 - 7.1.4 Levelling line
8 - 7.2 Other marking
8 - 8 PERFORMANCE REQUIREMENTS
8 - 8.1 Introduction
9 - 8.2 Sequence for conducting tests
9 - 8.3 Calibration accuracy
9 - 8.4 Stability
9 - 8.5 Resistance to leaching
9 - 8.6 Permanence of markings
9 - 8.6.1 Introduction
10 - 8.6.2 Resistance to chemical agents
10 - 8.7 Thermal shock resistance
11 - APPENDIX A - DETERMINATION OF RESISTANCE TO LEACHING
11 - A1 SCOPE
11 - A2 PRINCIPLE
11 - A3 REAGENTS
11 - A3.1 General
11 - A3.2 Leaching solutions
11 - A3.3 Standard lead solutions
11 - A4 TEMPERATURE OF TEST ENVIRONMENT
11 - A5 PROCEDURE
12 - A6 REPORT
13 - APPENDIX B - CHECK OF ACCURACY OF CALIBRATON
13 - B1 SCOPE
13 - B2 PROCEDURE
13 - B3 REPORT
14 - APPENDIX C - METHOD FOR ASSESSING RESISTANCE TO THERMAL SHOCK
14 - C1 SCOPE
14 - C2 APPARATUS
14 - C2.1 Stopwatch
14 - C2.2 Boiling water bath
14 - C2.3 Water bath
14 - C2.4 Pair of long-handled tongs
14 - C3 PROCEDURE
14 - C4 REPORT
15 - APPENDIX D - METHOD FOR ASSESSING PERMANENCE OF MARKINGS
15 - D1 SCOPE
15 - D2 PRINCIPLE
15 - D3 REAGENTS
15 - D4 APPARATUS
15 - D4.1 Constant temperature environment
15 - D4.2 Test bath(s)/container(s)
16 - D4.3 Control measure(s)
16 - D5 TEST PLAN
16 - D5.1 Preliminary considerations
16 - D5.2 Choice of plan
17 - D6 PROCEDURE
18 - D7 REPORT

Specifies requirements for two types of glass medicine measure-one of tumbler form and one of conical form.

Committee
CH-001
DocumentType
Standard
ISBN
0 7337 9142 5
Pages
13
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This Standard specifies requirements for two types of glass medicine measure - one of tumbler form and one of conical form.NOTE: Pediatric droppers are not manufactured from glass.

Originated as part of AS 2224 1978.
Previous edition AS 2224.1 1986.
Second edition 2009.

AS/NZS 2243.1:2005 Safety in laboratories Planning and operational aspects
AS/NZS 2243.2:2006 Safety in laboratories Chemical aspects

US$56.45