AS 2374.5-1982

Superseded

Superseded

View Superseded by

Power Transformers Ability To Withstand Short-Circuit

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

08-09-1982

Superseded date

05-17-2018

Superseded by

AS/NZS 60076.5:2012

US$42.56
Excluding Tax where applicable
Summarise this standard

1 - AS 2374, Part 5-1982 POWER TRANSFORMERS - ABILITY TO WITHSTAND SHORT-CIRCUIT
4 - PREFACE
4 - CONTENTS
5 - SECTION 1. SCOPE AND DEFINITIONS
5 - 1.1 SCOPE.
5 - 1.2 DEFINITIONS.
6 - SECTION 2. REQUIREMENTS WITH REGARD TO ABILITY TO WITHSTAND SHORT-CIRCUIT
6 - 2.1 GENERAL.
6 - 2.2 OVERCURRENT CONDITIONS.
6 - 2.2.1 Transformers with Two Separate Windings.
6 - 2.2.2 Transformers with more than Two Windings and Autotransformers
7 - 2.2.3 Booster Transformers.
7 - 2.2.4 Transformers Directly Associated with Other Apparatus
7 - 2.2.5 Special Transformers.
7 - 2.2.6 Tap-changing Equipment.
7 - 2.2.7 Neutral Terminals.
8 - SECTION 3. DEMONSTRATION OF ABILITY TO WITHSTAND SHORT-CIRCUIT
8 - 3.1 THERMAL ABILITY TO WITHSTAND SHORT-CIRCUIT.
8 - 3.1.1 General.
8 - 3.1.2 Value of the Symmetrical Short-circuit Current I for Transformers with Two Windings
8 - 3.1.3 Duration of the Symmetrical Short-circuit Current I
8 - 3.1.4 Maximum Permissible Value of the Highest Average Temperature
8 - 3.1.5 Calculation of the Temperature
8 - 3.1.6 Value of the Symmetrical Short-circuit Current I for Transformers with more than Two Windings and Autotransformers
9 - 3.2 DYNAMIC ABILITY TO WITHSTAND SHORT-CIRCUIT.
9 - 3.2.1 General.
9 - 3.2.2 Condition of the Transformer before the Short-circuit Tests.
9 - 3.2.3 Peak Value l^ for Two-winding Transformers.
9 - 3.2.4 Value and Duration of the Short-circuit Test Current for Two-windings Transformers
10 - 3.2.5 Short-circuit Testing Procedure for Transformers with Two Windings.
10 - 3.2.6 Detection of Faults.
12 - APPENDIX A - MODIFIED SHORT-CIRCUIT TEST PROCEDURES FOR CATEGORY I TRANSFORMERS

Specifies the design of power transformers as defined in AS 2374.1, and the requirements necessary both in regard to their ability to withstand short-circuit and the means of demonstrating that ability. Based on IEC 76-5.

Committee
EL-008
DocumentType
Standard
ISBN
0 7262 2641 6
Pages
8
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This standard specifies the design of power transformers as defined in AS 2374, Part 1, and the requirements necessary both in regard to their ability to withstand short-circuit and the means of demonstrating that ability.NOTES:1. Pending the publication of a standard that applies to dry-type transformers*, the requirements of this standard may be applied to dry-type transformers subject to agreement between the purchaser and the manufacturer and taking into account the principles established in Sections 2 and 3.2. A reduced schedule of short-circuit tests may be applied to Category I transformers by agreement between purchaser, manufacturer and testing authority. Guidance on the reduced schedule is given in Appendix A.

Reconfirmed 1987

⚠

A newer version of this standard is available.

View Current Edition
US$42.56
Excluding Tax where applicable