AS 2419.1:2017

AvailableSuperseded

AvailableSuperseded

Fire hydrant installations System design, installation and commissioning

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

11-06-2017

US$202.19
Excluding Tax where applicable
Summarise this standard

AS 2419.1 2017 specifies requirements for the design, installation and commissioning and testing of fire hydrant installations that are used for the protection of buildings, structures, storage yards, marinas and associated moored vessels, wharves and plant. Fire hydrant design standard.

Committee
FP-009
DocumentType
Standard
ISBN
978 1 76035 935 5
Pages
245
PublisherName
Standards Australia
Status
AvailableSuperseded
SupersededBy
Supersedes

This Standard specifies requirements for the design, installation, commissioning and testing of fire hydrant installations. It applies to on-site fire hydrant installations, that is, fire hydrant installations used to protect buildings, structures, storage yards, marinas and associated moored vessels, wharves and plant. Where a street fire hydrant(s) is to be used in lieu of an on-site feed fire hydrant(s), this Standard specifies requirements for its location, available pressure and flow as conditions for its inclusion in the designed fire hydrant installation. This Standard is not applicable to the design or performance of water agency town mains and street hydrants. The flow requirements detailed in this Standard, having been based on the floor area or volume of a building, are intended to provide sufficient water to enable firefighting operations to commence at a single location within a building or site. Where a risk assessment of a building or site determines that multiple ignitions or that rapid fire growth and spread is probable, then additional provisions have to be considered for inclusion.This Standard does not specify requirements for fire hydrant installations in special hazard areas.NOTES: 1 For guidance on means of demonstrating compliance with this Standard, see Appendix A.2 For information and guidance on fire hydrant installations in special hazard areas, see Appendix B.3 In circumstances where this Standard does not apply, the principles detailed in this Standard may be used as guidance for the design of a fire hydrant system in consultation with the relevant stakeholders.4 Manufacturers making a statement of compliance with this Australian Standard on a product or on packaging or promotional material are advised to ensure that such compliance is capable of being verified.

Originated as AS 2419-1980.
Revised and redesignated AS 2419.1-1988.
Fourth edition 2005.
Fifth edition 2017.

Frequently Asked Questions

AS 2419.1:2017 is used by hydraulic and fire designers, installers and certifiers of building fire hydrant systems. It is an Australian standard published by Standards Australia.

AS 2419.1:2017 is listed in this catalog as an Australian standard published by Standards Australia, with its region recorded as Australia only. The catalog does not record a New Zealand adoption of this document.

AS 2419.1:2017 sets requirements for the design, installation, commissioning and performance of fire hydrant systems. In practice it is applied by hydraulic and fire designers, installers and certifiers of building fire hydrant systems.

AS 2419.1:2017 is published by Standards Australia. It is an Australian standard.

AS 2419.1:2017 sets requirements for the design, installation, commissioning and performance of fire hydrant systems. It is an Australian standard published by Standards Australia.
⚠

A newer version of this standard is available.

View Current Edition