• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 4032.2-2005

Current

Current

Water supply - Valves for the control of hot water supply temperatures Tempering valves and end-of-line temperature-actuated devices

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

07-14-2015

US$97.21
Excluding Tax where applicable
Summarise this standard

The objective of this Standard is to provide manufacturers with requirements for tempering valves and end-of-line temperature-actuated devices that give reasonable protection to users against exposure to high or excessive fluctuations in mixed water temperatures caused by the following: - Maintaining an outlet temperature within specified limits, including shut-off of the cold water supply. - Closing the outlet when the mixed water temperature exceeds a specified maximum.

Committee
WS-026
DocumentType
Standard
ISBN
0 7337 7048 7
Pages
40
ProductNote
Reconfirmed 14/07/2015.This standard as been reconfirmed in Australia in 2015 and remains current in New Zealand. Reconfirmation Notice 14/07/2015
PublisherName
Standards Australia
Status
Current
Supersedes
UnderRevision

This Standard specifies requirements for the design, construction, testing and performance of - (a) tempering valves of nominal sizes not larger than DN32; and(b) end-of-line temperature-actuated devices of nominal size not larger than DN25,for use with heated water at - (i) continuous operating temperature not exceeding 85°C;(ii) temperature under emergency conditions, not exceeding 99°C; and(iii) continuous working pressure not exceeding 1400kPa.Devices complying with this Standard are intended to prevent a continuous discharge of water from the outlet in excess of 50°C under steady-state conditions.Transient discharges of water with a temperature in excess of this figure, which comply with the specified cumulative time/temperature factors, are acceptable.NOTE: Tempering valves, when adjusted to an outlet temperature not exceeding 50°C, and end-of-line devices may be used for temperature-limiting for ablution purposes, to minimize the risk of scalding, other than for use in health care, aged care, child care, care for people with disabilities and any other at-risk situations. Thermostatic mixing valves complying with AS4032.1, when adjusted to an outlet temperature not exceeding 45°C, are intended for use in health care, aged care, child care, care for people with disabilities and any other at-risk situations.

Originated as AS 4032.2-2002.
Second Edition 2005.
Reissued incorporating Amendment No. 1 (October 2006).
Reissued incorporating Amendment No. 2 (June 2009).

US$97.21
Excluding Tax where applicable