1 - AS/NZS 2430.3.2:1997 CLASSIFICATION OF HAZARDOUS AREAS - EXAMPLES OF AREA CLASSIFICATION-VEHICLE WORKSHOPS, VEHICLE...
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 REFERENCED DOCUMENTS
7 - 3 DEFINITIONS
7 - 3.1 Compressed natural gas (CNG)
7 - 3.2 Dispensing cabinet
7 - 3.3 Fuel dispensing unit
7 - 3.4 Liquefied petroleum gas (LPG)
7 - 3.5 Natural gas (NG)
7 - 3.6 Natural gas for vehicles (NGV)
7 - 4 VEHICLE WORKSHOPS
7 - 4.1 Scope
7 - 4.2 Classification of hazardous areas
7 - 4.2.1 Workshops at or above ground or street level
8 - 4.2.2 Workshops below ground or street level
8 - 4.2.3 Depressions, pits or sumps
8 - 5 VEHICLE PARKING AREAS
8 - 5.1 Scope
8 - 5.2 Classification of hazardous areas
8 - 5.2.1 Vehicle parking area
8 - 5.2.2 Depressions, pits or sumps
8 - 5.2.3 Vehicle turntables
9 - 6 RESIDENTIAL GARAGES
9 - 6.1 Scope
9 - 6.2 Classification of hazardous areas
9 - 6.2.1 Residential garage at or above ground or street level
9 - 6.2.2 Residential garage below ground or street level
9 - 7 PETROL, LPG AND NGV DISPENSING STATIONS
9 - 7.1 Scope
9 - 7.2 Classification of hazardous areas
9 - 7.2.1 Interior of petrol dispensing units in adequately ventilated locations (see Figure 7.1)
10 - 7.2.2 Exterior of petrol dispensing units in adequately ventilated locations (see Figure 7.2)
10 - 7.2.3 Exterior of petrol dispensing units mounted on a wharf/jetty in adequately ventilated locations (see Figure 7.4)
13 - 7.2.4 Petrol dispensing units in inadequately ventilated locations (see Figure 7.5)
13 - 7.2.5 Fill, vent and other pipes for underground petrol tanks (refer to Figure 7.6)
16 - 7.2.6 Interior of LPG dispensing units in adequately ventilated locations (see Figure 7.7)
17 - 7.2.7 Exterior of LPG dispensing units in adequately ventilated locations (see Figure 7.8)
17 - 7.2.8 Exterior of LPG dispensing units mounted on a wharf/jetty in adequately ventilated locations (see Figure 7.9)
21 - 7.2.9 Other LPG dispensing units in adequately ventilated locations (see Figure 7.10)
21 - 7.2.10 NGV dispensing units in adequately ventilated locations (see Figure 7.11)
22 - 7.2.11 Specific dispensing areas located at dispensing stations
23 - 7.2.12 Specific dispensing areas located at dispensing stations with vapour barrier
24 - 7.2.13 NGV compressor in adequately ventilated locations (see Figure 7.15)
24 - 7.2.14 Natural gas storage unit in adequately ventilated locations, whether in storage or installed for use (see Figure 7.15)
25 - 7.2.15 NGV compressor in inadequately ventilated locations (see Figure 7.16)
26 - 7.2.16 Storage units with vapour barrier (see Figure 7.17)
27 - 7.2.17 NGV compressor blow-down discharge vent
28 - 7.2.18 Relief valve discharge vent for NGV compressor and storage unit
28 - 7.2.19 Other areas
28 - 7.2.20 Underground wiring enclosures
28 - 8 POLLUTION CONTROL EQUIPMENT
28 - 8.1 General
28 - 8.1.1 Scope
28 - 8.1.2 Pumps
28 - 8.2 Coalescing plate separator units in adequately ventilated locations
29 - 8.3 Coalescing plate separator units in inadequately ventilated locations
30 - 8.4 Waste collection storage vessels, drains, sumps or pits
30 - 9 AIRCRAFT HANGARS AND REFUELLING AREAS
30 - 9.1 Scope
30 - 9.2 Classification of hazardous areas
30 - 9.2.1 Pits or depressions
31 - 9.2.2 Hangar floor-Petrol, Avgas and JP4 type fuels
31 - 9.2.3 Around aircraft in hangars-All fuels
32 - 9.2.4 Other hangar areas

Provides guidance on the classification of areas associated with vehicle workshops, vehicle parking areas, fuel dispensing stations and aircraft hangars. It includes specific examples of classification for the aforementioned areas as well as for residential garages and pollution control equipment. To be read in conjunction with AS/NZS 2430.3.1:1997.

Committee
MS-011
DocumentType
Standard
ISBN
0 7337 1650 4
Pages
28
ProductNote
See also AS 2430.3-1991
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard provides examples of area classification for areas associated with vehicle workshops, vehicle parking, fuel dispensing stations and aircraft hangars. The Standard is part of the AS/NZS 2430.3 series, which recommends the classification of several commonly occurring situations, and should be read in conjunction with AS/NZS 2430.3.1.

First publlished in Australia in part as part of AS 1076.2-1977.
AS 2430.1 first published 1981.
AS 1076.2-1977 and AS 2430.1-1981 revised, amalgamated and designated AS 2430.1-1982.
AS 2430.1-1982 revised and redesignated in part as AS 2430.3-1987.
Second edition 1991.