AS/NZS 3001:2001

Superseded

Superseded

View Superseded by

Electrical installations - Relocatable premises (including caravans and tents) and their site installations

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-2001

Superseded date

07-08-2024

Superseded by

AS/NZS 3001:2008

US$81.63
Excluding Tax where applicable
Summarise this standard

1 - AS/NZS 3001:2001 ELECTRICAL INSTALLATIONS-RELOCATABLE PREMISES(INLUDING CARAVANS AND TENTS) AND THEIR SITE INSTALLATIONS
4 - PREFACE
5 - FOREWORD
6 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
8 - 1.2 APPLICATION
8 - 1.3 REFERENCED DOCUMENTS
9 - 1.4 DEFINITIONS
9 - 1.4.1 Amenities
9 - 1.4.2 Annex
9 - 1.4.3 Caravan park
9 - 1.4.4 Camping area
9 - 1.4.5 Detachable connection
9 - 1.4.6 Direct connection
9 - 1.4.7 Occupier
9 - 1.4.8 Outlet box
9 - 1.4.9 Registrable
9 - 1.4.10 Relocatable premises
10 - 1.4.11 Service pillar
10 - 1.4.12 Site
10 - 1.4.13 Tent
10 - 1.5 ALTERATIONS, ADDITIONS AND REPAIRS
11 - SECTION 2 SITE SUPPLY
11 - 2.1 WIRING DETAILS
11 - 2.1.1 General
11 - 2.1.2 Underground wiring
11 - 2.1.3 Overhead wiring
11 - 2.1.4 Earthing
12 - 2.2 MAXIMUM DEMAND
12 - 2.2.1 Mains and sub-mains
12 - 2.3 SWITCHBOARDS PROVIDING SITE SUPPLY
12 - 2.3.1 General
12 - 2.3.2 Service pillars
15 - 2.3.3 Other switchboards
15 - 2.4 OTHER SOCKET-OUTLETS
15 - 2.5 MULTIPLE RELOCATABLE PREMISES OCCUPYING ONE SITE
15 - 2.6 SITES FOR LOW CONSUMPTION PREMISES
15 - 2.7 TESTING OF RESIDUAL CURRENT DEVICES (RCDs)
15 - 2.7.1 Testing regime
16 - 2.7.2 Recording of results
17 - SECTION 3 RELOCATABLE PREMISES ELECTRICAL INSTALLATION
17 - 3.1 GENERAL
17 - 3.2 PROVISION FOR CONNECTION TO SITE SUPPLY
17 - 3.2.1 Detachable connection at the relocatable premises
18 - 3.2.2 Direct connection at the relocatable premises
18 - 3.2.3 Multiple connections at the relocatable premises
18 - 3.3 CONTROL AND PROTECTION
18 - 3.3.1 Installation supplied by detachable connection
19 - 3.3.2 Installation supplied by direct connection
19 - 3.4 WIRING SYSTEM
19 - 3.4.1 Size and type of cable
19 - 3.4.2 Protection from damage
19 - 3.4.3 Fixing
20 - 3.4.4 Isolation and segregation
20 - 3.5 EARTHING
20 - 3.5.1 Detachable connection
21 - 3.5.2 Direct connection
21 - 3.5.3 Equipotential bonding
22 - 3.6 ACCESSORIES
22 - 3.6.1 Mounting
22 - 3.6.2 Switches
22 - 3.6.3 Socket-outlets
22 - 3.6.4 Output terminals
22 - 3.7 PERMANENTLY CONNECTED APPLIANCES
22 - 3.7.1 Control
22 - 3.7.2 Over-temperature cut- out
22 - 3.8 EXTRA-LOW-VOLTAGE TRANSFORMERS
22 - 3.9 ELECTRICAL INSTALLATIONS IN AREAS CONTAINING A BATH OR SHOWER
23 - 3.10 TESTING
24 - SECTION 4 TENT AND NON-RIGID ANNEX ELECTRICAL INSTALLATIONS
24 - 4.1 GENERAL
24 - 4.2 SUPPLY TO ELECTRICAL EQUIPMENT
24 - 4.2.1 One item to be supplied
24 - 4.2.2 More than one item to be supplied
24 - 4.3 CONNECTION OF SUPPLY
24 - 4.3.1 General
24 - 4.3.2 Multiple relocatable premises occupying the one site
24 - 4.3.3 Restriction on connection
25 - 4.3.4 Prohibited connections
26 - 4.4 OUTLET BOX
26 - 4.4.1 General
26 - 4.4.2 Construction
26 - 4.4.3 Termination of supply lead
26 - 4.4.4 Socket-outlets
26 - 4.4.5 Earthing
26 - 4.4.6 Overcurrent protection
26 - 4.4.7 Protection against earth leakage current
27 - 4.4.8 Control switches
27 - 4.4.9 Marking
27 - 4.5 LIGHTING
27 - 4.5.1 Handlamps
27 - 4.5.2 Lighting equipment other than handlamps
28 - SECTION 5 CONNECTION OF RELOCATABLE PREMISES TO SITE SUPPLY
28 - 5.1 SUPPLY LEAD
28 - 5.1.1 General
28 - 5.1.2 Technical details
28 - 5.1.3 Length
29 - 5.1.4 Coiled leads
29 - 5.2 PROTECTION AGAINST EARTH LEAKAGE CURRENT
29 - 5.3 INSTALLATION OF SUPPLY LEAD
30 - APPENDIX A - CALCULATION OF MAXIMUM DEMAND
30 - A1 INTRODUCTION
30 - A2 PROPOSED CALCULATION VALUES
30 - A2.1 Amenities
30 - A2.2 Service pillars
31 - A3 DETERMINATION OF CALCULATED MAXIMUM DEMAND
32 - APPENDIX B - PROVISION OF CONNECTION INSTRUCTIONS FOR SITES

Specifies requirements, in addition to those of AS/NZS 3000:2000, for electrical installations in relocatable premises, including caravans and tents, and in caravan parks and camping areas.

Committee
EL-001
DocumentType
Standard
ISBN
0 7337 4162 2
Pages
26
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out requirements for electrical installations associated with relocatable premises intended for connection to low-voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.).It includes requirements for the internal electrical installation of applicable relocatable premises and for certain types of electrical installations intended to supply electrical power to those premises. Such installations include caravan parks and camping areas with powered sites but excludes fairgrounds and temporary camping sites, which are subject to the requirements of AS/NZS 3002, and construction and demolition sites, which are subject to the requirements of AS/NZS 3012.Relocatable premises within the coverage of this Standard include the following:(a) Registrable vehicles offering accommodation, including caravans, camper vans, motor homes, camper trailers and livestock or car transporters with accommodation included.(b) In New Zealand, other registrable premises including food and drink vending vans and trailers, mobile x-ray caravans, mobile blood banks, walk-through educational display caravans and trailers, mobile classrooms, television outside broadcast vans. (c) Non-registrable relocatable premises including relocatable homes, transportable huts, tents for accommodation, and rigid and non-rigid annexes to premises referred to in (a) and (b).(d) Temporary site offices, cloakrooms, meeting offices, dormitories, canteens, toilets or other facilities provided on construction and demolition sites.(e) In New Zealand, registrable display units not requiring occupation, e.g. mobile electronic score boards and advertising signs, mobile traffic information signs This Standard does not apply to the following electrical installations: (i) Relocatable premises with a permanently connected electricity supply and not intended to be relocated, e.g. tramcars, buses or caravans rendered immobile, transportable sheds.These are subject to the requirements of AS/NZS 3000.(ii) Registrable vehicles with fixed wiring that are amusement rides or concessions. These are subject to the requirements of AS 3533.(iii) In Australia other registrable premises including food and drink vending vans and trailers, mobile x-ray caravans, mobile blood banks, walk-through educational display caravans and trailers, mobile classrooms, television outside broadcast vans.NOTE: It is intended that the inclusion of at least some of these items in the scope for Australia will be investigated in the near future.(iv) Relocatable premises, without fixed wiring, for provision of entertainment. e.g. circus and carnival tents, temporary vending stalls.These are subject to the requirements of AS/NZS 3002.(v) In Australia, registrable display units not requiring occupation, e.g. mobile electronic score boards and advertising signs, mobile traffic information signs.

First published as AS 3001-1959.
Second edition 1966.
Third edition 1977.
Fourth edition 1981.
AS 3005 first published 1982.
Fifth edition AS 3001-1985.
Sixth edition 1990.
AS 3001-1990 and AS 3005-1982 jointly revised, amalgamated and redesignated as AS/NZS 3001:2001.

⚠

A newer version of this standard is available.

View Current Edition
US$81.63
Excluding Tax where applicable