1 - AS / NZS 3108:1994 APPROVAL AND TEST SPECIFICATION - PARTICULAR REQUIREMENTS FOR ISOLATING TRANSFORMERS AND SAFETY ISOLATING
4 - PREFACE
7 - CONTENTS
9 - CHAPTER 1 GENERAL REQUIREMENTS
9 - 1 SCOPE
9 - 2 DEFINITIONS
10 - 2.1 Safety extra-low voltage (SELV)
10 - 2.2 Power transformer
10 - 2.3 Isolating transformer
10 - 2.4 Safety isolating transformer
10 - 2.5 Flush-type transformer
10 - 2.6 Associated transformer
10 - 2.7 Incorporated transformer
10 - 2.8 Transformer for specific use
10 - 2.9 Input winding
10 - 2.10 Output winding
10 - 2.11 Rated supply voltage
10 - 2.12 Rated supply voltage range
10 - 2.13 Rated frequency
10 - 2.14 Rated output current
11 - 2.15 Rated output voltage
11 - 2.16 Rated power factor
11 - 2.17 Rated output
11 - 2.18 No-load input
11 - 2.19 No-load output voltage
11 - 2.20 Short-circuit voltage
11 - 2.21 Power supply cord
11 - 2.22 Detachable part
11 - 2.23 Tool
11 - 2.24 Basic insulation
12 - 2.25 Supplementary insulation
12 - 2.26 Double insulation
12 - 2.27 Reinforced insulation
12 - 2.28 Class I transformer
12 - 2.29 Class II transformer
12 - 2.30 Class III transformer
12 - 2.31 Short-circuit proof transformer
13 - 2.32 Non-inherently short-circuit proof transformer
13 - 2.33 Inherently short-circuit proof transformer
13 - 2.34 Fail-safe transformer
13 - 2.35 Non-short-circuit proof transformer
13 - 2.36 Portable transformer
13 - 2.37 Hand-held transformer
13 - 2.38 Stationary transformer
13 - 2.39 All-pole disconnection
13 - 2.40 Thermal cutout
13 - 2.41 Self-resetting thermal cutout
13 - 2.42 Non-self-resetting thermal cutout
13 - 2.43 Overload release
13 - 2.44 Body
14 - 2.45 Accessible part
14 - 2.46 Rated ambient temperature
14 - 2.47 Clearance
14 - 2.48 Creepage distance
14 - 2.49 Working voltage
14 - 2.50 Pollution
14 - 2.51 Micro-environment
14 - 2.52 Degree of pollution in the micro-environment
14 - 2.53 Protective separation
15 - 2.54 Protective screening
15 - 3 GENERAL REQUIREMENTS
15 - 3.1 Design and construction
15 - 4 GENERAL NOTES ON TESTS
15 - 4.1 Type of tests
15 - 4.2 Sampling
15 - 4.3 Order of tests
15 - 4.4 Temperature
15 - 4.5 Test voltages
15 - 4.6 Position during tests
16 - 4.7 Test measurements
16 - 4.8 Transformers with a power supply cord
16 - 4.9 Class I transformers with parts of Class II construction
16 - 4.10 Flush-type transformers
16 - 4.11 Transformers for specific use
16 - 4.12 Associated transformers
17 - 4.13 IP 00 transformers
17 - 4.201 Electronic circuits associated with transformers
17 - 5 RATING
17 - 6 CLASSIFICATION
17 - 6.1 Electric shock protection
17 - 6.2 Short-circuit protection
17 - 6.3 Enclosure protection
17 - 6.4 Mobility
17 - 7 MARKING
17 - 7.1 General
18 - 7.2 Transformers with IP 00 protection or associated transformers
18 - 7.3 Transformers with adjustable supply voltages
18 - 7.4 Transformers with tapped or multiple output windings
19 - 7.5 Additional marking for short-circuit proof, non-short-circuit proof and fail-safe transformers
19 - 7.6 Terminals
19 - 7.7 Connection markings
19 - 7.8 Transformers with Type X, Y, and Z attachments
20 - 7.9 Symbols
21 - 7.10 Switches and regulating devices
21 - 7.11 Position of marking
22 - 7.12 Legibility and durability
22 - 8 PROTECTION AGAINST ELECTRIC SHOCK
22 - 8.1 Construction and enclosure
23 - 8.2 Prohibited connections
23 - 8.3 Mechanical strength
24 - 8.4 Shafts, handles, operating levers, knobs and the like
24 - 8.5 Insulation
24 - 8.6 Separation of input and output windings
25 - 8.7 Prohibited use of capacitors
25 - 9 CHANGE OF INPUT VOLTAGE SETTING
26 - 10 OUTPUT VOLTAGE AND OUTPUT CURRENT UNDER LOAD
26 - 10.1 Output voltage
26 - 10.2 Confirmation of output markings
26 - 11 NO-LOAD OUTPUT VOLTAGE
26 - 12 SHORT-CIRCUIT VOLTAGE
26 - 13 HEATING
26 - 13.1 Temperature during normal use
31 - 14 SHORT-CIRCUIT AND OVERLOAD PROTECTION
31 - 14.1 General
33 - 15 MECHANICAL STRENGTH
33 - 15.1 General
34 - 15.2 Impact test
34 - 15.3 Drop test for portable transformers without integral pins
34 - 15.4 Transformers with integral pins
34 - 16 PROTECTION AGAINST HARMFUL INGRESS OF WATER AND MOISTURE
34 - 16.1 Enclosures
35 - 16.2 Effects of humidity
35 - 17 INSULATION RESISTANCE AND ELECTRIC STRENGTH
35 - 17.1 General
37 - 18 CONSTRUCTION
37 - 18.1 General
37 - 18.2 Materials
38 - 18.3 Permissible types
38 - 18.4 Contact between accessible metal and conduits
38 - 18.5 Removal and replacement of insulation
38 - 18.6 Class I and Class II transformers
39 - 18.7 Supplementary and reinforced insulation
39 - 18.8 Separation of input and output terminals
39 - 18.9 Fixing of handles, levers and the like
39 - 18.10 Fixing of covers
40 - 18.11 Transformers provided with pins
40 - 18.12 Protection index
40 - 18.13 Transformers with a particular protection index
40 - 18.14 Class I transformers
40 - 18.201 Output facilities
41 - 19 COMPONENTS
41 - 19.1 General
41 - 19.2 Switches
41 - 19.3 Socket-outlets
41 - 19.4 Breaking capacity of thermal cutouts and overload releases
42 - 19.5 Prohibition of self-resetting thermal cutouts
42 - 19.6 Prohibited components
42 - 19.7 Operation of overload protection devices
42 - 19.201 Mounting of output protection
42 - 20 INTERNAL WIRING
42 - 20.1 Protection
42 - 20.2 Openings
42 - 20.3 Bare conductors
42 - 20.4 Fixing of internal wiring
42 - 20.5 Insulated conductors
43 - 21 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS
43 - 21.1 Separate entries for input and output wiring
43 - 21.2 Stationary transformers
43 - 21.3 Portable transformers
43 - 21.4 Cables and cords used for connections
43 - 21.5 Cross-sectional area of power supply flexible cables and cords
44 - 21.6 Fitting of plugs
44 - 21.7 Power supply cord attachment
48 - 22 TERMINALS FOR EXTERNAL CONDUCTORS
48 - 22.1 Types of fixings
48 - 22.2 Screws and nuts which clamp external conductors
49 - 22.3 Compatibility between terminals and conductors
49 - 22.4 Clamping arrangements for terminals for Type X attachment
49 - 22.5 Clamping of conductors
50 - 22.6 Grouping of terminals
50 - 22.7 Terminal blocks and similar devices
50 - 22.8 Terminals for Type X attachment
50 - 22.9 Design and position of terminals
50 - 22.10 Dimensions of pillar terminals
51 - 22.11 Dimensions of screw terminals
52 - 22.12 Dimensions of stud terminals
53 - 22.13 Mechanical strength of terminals
53 - 22.14 Prohibition of contact between terminals and accessible metal
53 - 23 PROVISION FOR EARTHING
53 - 23.1 General
54 - 23.2 Design of earthing terminal
54 - 23.3 Prevention of corrosion of earthing terminal
54 - 23.4 Prohibition of earthing of socket-outlets
54 - 23.5 Resistance of earthing connection
55 - 24 SCREWS AND CONNECTIONS
55 - 24.1 Mechanical strength
56 - 24.2 Engagement of thread
56 - 24.3 Contact pressure of electrical connections
56 - 24.4 Space-threaded and thread-cutting screws
57 - 24.5 Use of screws and rivets
57 - 25 CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION
57 - 26 RESISTANCE TO HEAT, ABNORMAL HEAT, FIRE AND TRACKING
57 - 26.1 Resistance of external parts of insulating material to heat
57 - 26.2 Resistance of external parts of insulating material to fire
61 - 26.3 Parts of insulating material retaining live parts in position
62 - 26.4 Resistance of insulating material to abnormal heat
62 - 26.5 Resistance to tracking
62 - 27 RESISTANCE TO RUSTING
63 - APPENDIX 1A - TESTS DURING PRODUCTION
63 - 1A1 GENERAL
63 - 1A2 EARTHING CONTINUITY TEST
63 - 1A3 CHECKING OF NO-LOAD OUTPUT VOLTAGE AND NO-LOAD CURRENT
63 - 1A4 ELECTRIC STRENGTH TEST
63 - 1A5 CHECKING OF MOUNTING OF PROTECTIVE DEVICES
64 - APPENDIX 1B - EXAMPLES OF CONSTRUCTION OF WINDINGS TO BE USED AS A GUIDE FOR CLAUSE 8.6
64 - 1B1 COIL- FORMERS
65 - 1B2 WINDINGS
67 - APPENDIX IC - EXAMPLES OF POINTS OF APPLICATION OF TEST VOLTAGES
69 - APPENDIX 1D - MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES
74 - APPENDIX 1E - EXAMPLES OF POINTS OF MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES
76 - CHAPTER 2 SUPPLEMENTARY REQUIREMENTS FOR ISOLATING TRANSFORMERS FOR GENERAL USE AND SHAVER TRANSFORMERS
76 - INTRODUCTION
76 - 1 SCOPE
76 - 2 DEFINITIONS
76 - 2.101 Shaver supply transformer
76 - 2.102 Shaver supply unit
76 - 3 GENERAL REQUIREMENTS
76 - 4 GENERAL NOTES ON TESTS
76 - 5 RATING
76 - 5.101 Rated output voltage
77 - 5.102 Rated output
77 - 5.103 Rated input voltage
77 - 6 CLASSIFICATION
77 - 7 MARKING
77 - 7.1 General
77 - 7.9 Symbols
77 - 7.11 Position of marking
77 - 8 PROTECTION AGAINST ELECTRIC SHOCK
77 - 8.1 Construction and enclosure
78 - 8.2 Prohibited connections
78 - 9 CHANGE OF INPUT VOLTAGE SETTING
78 - 10 OUTPUT VOLTAGE AND OUTPUT CURRENT UNDER LOAD
78 - 11 NO-LOAD OUTPUT VOLTAGE
78 - 11.101 Maximum no-load voltage
78 - 11.102 Difference between output voltages at no-load and at rated output
78 - 12 SHORT- CIRCUIT VOLTAGE
78 - 13 HEATING
79 - 14 SHORT-CIRCUIT AND OVERLOAD PROTECTION
79 - 14.1 General
79 - 15 MECHANICAL STRENGTH
79 - 16 PROTECTION AGAINST HARMFUL INGRESS OF WATER AND MOISTURE
79 - 17 INSULATION RESISTANCE AND ELECTRIC STRENGTH
79 - 18 CONSTRUCTION
79 - 18.6 Class I and Class II transformers
79 - 18.7 Supplementary and reinforced insulation
79 - 18.101 Mounting boxes
79 - 18.102 Output windings
79 - 18.103 Separation of output windings and connection to socket- outlet
79 - 18.104 Socket- outlets
79 - 18.105 Replacement of non- self- resetting thermal cutouts
80 - 19 COMPONENTS
80 - 19.2 Switches
80 - 19.5 Prohibition of self-resetting thermal cutouts
80 - 20 INTERNAL WIRING
80 - 21 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS
80 - 21.4 Cables and cords used for connections
80 - 22 TERMINALS FOR EXTERNAL CONDUCTORS
80 - 22.5 Clamping of conductors
80 - 22.8 Terminals for Type X attachment
81 - 23 PROVISION FOR EARTHING
81 - 23.4 Prohibition of earthing of socket-outlets
81 - 24 SCREWS AND CONNECTIONS
81 - 25 CREEPAGE DISTANCES AND CLEARANCES AND DISTANCES THROUGH INSULATION
81 - 26 RESISTANCE TO HEAT, ABNORMAL HEAT, FIRE AND TRACKING
81 - 27 RESISTANCE TO RUSTING
82 - CHAPTER 3 SUPPLEMENTARY REQUIREMENTS FOR SAFETY ISOLATING TRANSFORMERS
82 - INTRODUCTION
83 - SECTION 1 SAFETY ISOLATING TRANSFORMERS FOR GENERAL USE
83 - 1 SCOPE
83 - 2 DEFINITIONS
83 - 3 GENERAL REQUIREMENTS
83 - 4 GENERAL NOTES ON TESTS
83 - 5 RATING
83 - 5.101 Rated output voltage
83 - 5.102 Maximum rated output
83 - 6 CLASSIFICATION
83 - 7 MARKING
83 - 7.101 Instruction sheet
84 - 8 PROTECTION AGAINST ELECTRIC SHOCK
84 - 8.1 Construction and enclosure
84 - 9 CHANGE OF INPUT VOLTAGE SETTING
84 - 10 OUTPUT VOLTAGE AND OUTPUT CURRENT UNDER LOAD
84 - 11 NO-LOAD OUTPUT VOLTAGE
84 - 11.101 Maximum no-load output voltage
84 - 11.102 Difference between output voltage at no- load and at rated output
85 - 12 SHORT-CIRCUIT VOLTAGE
85 - 13 HEATING
85 - 14 SHORT-CIRCUIT AND OVERLOAD PROTECTION
85 - 15 MECHANICAL STRENGTH
85 - 16 PROTECTION AGAINST HARMFUL INGRESS OF WATER AND MOISTURE
85 - 17 INSULATION RESISTANCE AND ELECTRIC STRENGTH
85 - 18 CONSTRUCTION
85 - 18.6 Class I and Class II Transformers
85 - 18.7 Supplementary and reinforced insulation
85 - 19 COMPONENTS
85 - 20 INTERNAL WIRING
85 - 21 SUPPLY CONNECTION AND SUPPLY FLEXIBLE CABLES OR CORDS
85 - 21.4 Cables and cords used for connections
86 - 22 TERMINALS FOR EXTERNAL CONDUCTORS
86 - 22.5 Clamping of conductors
86 - 22.8 Terminals for Type X attachment
86 - 23 PROVISION FOR EARTHING
86 - 24 SCREWS AND CONNECTIONS
86 - 25 CREEPAGE DISTANCES AND CLEARANCES AND DISTANCES THROUGH INSULATION
86 - 26 RESISTANCE TO HEAT, ABNORMAL HEAT, FIRE AND TRACKING
86 - 27 RESISTANCE TO RUSTING
87 - SECTION 2 TRANSFORMERS FOR TOYS
87 - 1 SCOPE
87 - 2 DEFINITIONS
87 - 2.101 Transformer for toys
87 - 3 GENERAL REQUIREMENTS
87 - 4 GENERAL NOTES ON TESTS
87 - 5 RATING
87 - 5.101 Rated output voltage
87 - 5.102 Rated output
87 - 5.103 Rated supply voltage
87 - 6 CLASSIFICATION
87 - 7 MARKING
87 - 7.1 General
87 - 7.9 Symbols
88 - 8 PROTECTION AGAINST ELECTRIC SHOCK
88 - 8.1 Construction and enclosure
88 - 8.1 Construction and enclosure
88 - 9 CHANGE OF INPUT VOLTAGE SETTING
88 - 10 OUTPUT VOLTAGE AND OUTPUT CURRENT UNDER LOAD
88 - 11 NO-LOAD OUTPUT VOLTAGE
88 - 11.101 Maximum no-load output voltage
88 - 11.102 Difference between output voltage at no-load and at rated output
88 - 12 SHORT-CIRCUIT VOLTAGE
89 - 13 HEATING
89 - 14 SHORT-CIRCUIT AND OVERLOAD PROTECTION
89 - 14.1 General
89 - 14.3 Non- inherently short-circuit proof transformers
89 - 15 MECHANICAL STRENGTH
90 - 16 PROTECTION AGAINST HARMFUL INGRESS OF WATER AND MOISTURE
90 - 17 INSULATION RESISTANCE AND ELECTRIC STRENGTH
90 - 18 CONSTRUCTION
90 - 18.1 General
90 - 18.6 Class II transformers
90 - 18.7 Supplementary and reinforced insulation
90 - 18.101 Transformers with a. c. terminals in the output circuit
91 - 19 COMPONENTS
91 - 19.3 Socket outlets
91 - 19.4 Breaking capacity of thermal cut- outs and overload releases
91 - 19.101 Non- self- resetting thermal cutouts and overload releases
91 - 19.102 Control devices
91 - 20 INTERNAL WIRING
92 - 21 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS
92 - 21.4 Cables and cords used for connection
92 - 21.5 Cross-sectional area of power supply flexible cables and cords
92 - 22 TERMINALS FOR EXTERNAL CONDUCTORS
92 - 22.5 Clamping of conductors
92 - 22.8 Terminals for Type X attachment
92 - 23 PROVISION FOR EARTHING
92 - 24 SCREWS AND CONNECTIONS
92 - 25 CREEPAGE DISTANCES AND CLEARANCES AND DISTANCES THROUGH INSULATION
92 - 26 RESISTANCE TO HEAT, ABNORMAL HEAT, FIRE AND TRACKING
92 - 27 RESISTANCE TO RUSTING
93 - SECTION 3 BELL TRANSFORMERS
93 - 1 SCOPE
93 - 2 DEFINITIONS
93 - 2.101 Bell transformer
93 - 3 GENERAL REQUIREMENTS
93 - 4 GENERAL NOTES ON TESTS
93 - 4.10 Flush-type transformers
93 - 4.10 Flush-type transformers
93 - 5 RATING
93 - 5.101 Rated output voltage
93 - 5.102 Rated output current
93 - 5.103 Rated supply voltage
93 - 5.104 Rated output power
93 - 6 CLASSIFICATION
94 - 6.2 Short-circuit protection
94 - 6.101 Method of mounting
94 - 7 MARKING
94 - 7.1 General
94 - 7.9 Symbols
94 - 8 PROTECTION AGAINST ELECTRIC SHOCK
94 - 8.1 Construction and enclosure
94 - 8.201 Protection against contact with windings and live parts
94 - 9 CHANGE OF INPUT VOLTAGE SETTING
94 - 10 OUTPUT VOLTAGE AND OUTPUT CURRENT UNDER LOAD
95 - 11 NO-LOAD OUTPUT VOLTAGE
95 - 11.101 Maximum no-load output voltage
95 - 11.102 Difference between output voltage at no- load and at rated output
95 - 12 SHORT-CIRCUIT VOLTAGE
95 - 13 HEATING
96 - 14 SHORT-CIRCUIT AND OVERLOAD PROTECTION
96 - 14.1 General
96 - 14.1 General
96 - 15 MECHANICAL STRENGTH
96 - 15.2 Impact test
96 - 16 PROTECTION AGAINST HARMFUL INGRESS OF WATER AND MOISTURE
96 - 17 INSULATION RESISTANCE AND ELECTRIC STRENGTH
96 - 18 CONSTRUCTION
96 - 18.1 General
96 - 18.1 General
97 - 18.6 Class II transformers
97 - 18.7 Supplementary and reinforced insulation
97 - 18.13 Transformers with a particular protection index
97 - 18.13 Transformers with a particular protection index
97 - 18.101 Transformers mounted in consumer distribution boxes
97 - 19 COMPONENTS
97 - 19.2 Switches
97 - 19.2 Switches
97 - 19.4 Breaking capacity of thermal cutouts and overload releases
97 - 19.4 Breaking capacity of thermal cutouts and overload releases
98 - 19.5 Prohibition of self-resetting thermal cutouts
98 - 20 INTERNAL WIRING
98 - 21 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS
98 - 21.1 Separate entries for input and output wiring
98 - 21.4 Cables and cords used for connection
99 - 22 TERMINALS FOR EXTERNAL CONDUCTORS
99 - 22.5 Clamping of conductors
99 - 22.8 Terminals for Type X attachment
99 - 23 PROVISION FOR EARTHING
99 - 24 SCREWS AND CONNECTIONS
99 - 24.2 Engagement of thread
99 - 25 CREEPAGE DISTANCES AND CLEARANCES AND DISTANCES THROUGH INSULATION
99 - 26 RESISTANCE TO HEAT, ABNORMAL HEAT, FIRE AND TRACKING
99 - 27 RESISTANCE TO RUSTING
100 - SECTION 4 TRANSFORMERS FOR CLASS III HANDLAMPS
100 - 1 SCOPE
100 - 2 DEFINITIONS
100 - 2.101 Transformers for Class III handlamps
100 - 3 GENERAL REQUIREMENTS
100 - 4 GENERAL NOTES ON TESTS
100 - 5 RATING
100 - 5.101 Rated output voltage
100 - 6 CLASSIFICATION
100 - 7 MARKING
100 - 7.1 General
100 - 7.9 Symbols
101 - 8 PROTECTION AGAINST ELECTRICAL SHOCK
101 - 8.1 Construction and enclosure
101 - 9 CHANGE OF INPUT VOLTAGE SETTING
101 - 10 OUTPUT VOLTAGE AND OUTPUT CURRENT UNDER LOAD
101 - 11 NO-LOAD OUTPUT VOLTAGE
101 - 11.101 Maximum no- load output voltage
101 - 11.102 Difference between output voltage at no- load and the voltage at half the rated output
101 - 12 SHORT- CIRCUIT VOLTAGE
101 - 13 HEATING
102 - 14 SHORT- CIRCUIT AND OVERLOAD PROTECTION
102 - 15 MECHANICAL STRENGTH
102 - 16 PROTECTION AGAINST HARMFUL INGRESS OF WATER AND MOISTURE
102 - 17 INSULATION RESISTANCE AND ELECTRIC STRENGTH
102 - 18 CONSTRUCTION
102 - 18.6 Class II transformers
102 - 18.7 Supplementary and reinforced insulation
102 - 19 COMPONENTS
102 - 20 INTERNAL WIRING
102 - 21 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS
102 - 21.4 Cables and cords used for connections
103 - 22 TERMINALS FOR EXTERNAL CONDUCTORS
103 - 22.5 Clamping of conductors
103 - 22.8 Terminals for Type X attachment
103 - 23 PROVISION FOR EARTHING
103 - 24 SCREWS AND CONNECTIONS
103 - 25 CREEPAGE DISTANCES AND CLEARANCES DISTANCES THROUGH INSULATION
103 - 26 RESISTANCE TO HEAT, ABNORMAL HEAT, FIRE AND TRACKING
103 - 27 RESISTANCE TO RUSTING
110 - ANNEX A - VARIANT TO CLAUSE 22, TERMINALS FOR EXTERNAL CONDUCTORS
110 - 22.3 Compatibility between terminals and conductors
110 - 22.10 Dimensions of pillar terminals
111 - 22.11 Dimensions of screw terminals
111 - 22.12 Dimensions of stud terminals
111 - 22.13 Mechanical strength of terminals
116 - ANNEX B - LIST OF VARIATIONS BETWEEN THIS STANDARD AND IEC 742:1983