AS/NZS 3823.1.1:1998
AvailableSuperseded
Performance of electrical appliances - Airconditioners and heat pumps Non-ducted airconditioners and heat pumps - Testing and rating for performance
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
08-05-1998
Specifies the testing Standards for room airconditioners. This Standard is technically equivalent to and reproduced from ISO 5151:1994.
| Committee |
EL-015
|
| DocumentType |
Standard
|
| ISBN |
0 7337 1976 7
|
| Pages |
52
|
| PublisherName |
Standards Australia
|
| Status |
AvailableSuperseded
|
| SupersededBy | |
| Supersedes | |
| UnderRevision |
1.1 This International Standard specifies the standard conditions on which the ratings of single-package and split-system non-ducted air conditioners employing air- and water-cooled condensers and heat pumps employing air-cooled condensers are based, and the test methods to be applied for determination of the various ratings. This International Standard is limited to systems utilizing a single refrigeration circuit and having one evaporator and one condenser.NOTE 1 For the purposes of this International Standard, the term "equipment" will be used to mean "non-ducted air conditioners and/or non-ducted heat pumps".1.2 This International Standard also specifies the test conditions and the corresponding test procedures for determining various performance characteristics of these non-ducted air conditioners and heat pumps.1.3 It does not apply to the testing and rating of:a) water-source heat pumps;b) multiple split-system1)air conditioners and heat pumps;c) units designed for use with additional ducting; ord) mobile (windowless) units having a condenser exhaust duct.1.4 Clause 4 of this International Standard covers the rating and testing conditions for non-ducted air conditioners and heal pumps when used for cooling.1.5 Clause 5 of this International Standard covers the rating and testing conditions for non-ducted air conditioners and heat pumps when used for heating. The means for heating may be the heat pump refrigeration cycle or electrical resistance.1.6 Annex A establishes testing procedures. Annex B describes the test facilities for the calorimeter method. Annex C provides formulae for the calculation of heating and cooling capacities. Annex D describes instruments which can be used in making measurements, and annex E describes methods for measuring air-flow. Annex F describes the outdoor air-enthalpy test method. Annex G gives a list of symbols used in the annexes.
| Standards | Relationship |
| ISO 5151:1994 | Identical |
First published in Australia as AS B210-1966.
Revised and redesignated AS 1861-1976.
Second edition 1981.
Revised and redesignated AS 1861.1-1988.
Jointly revised and redesignated AS/NZS 3823.1.1:1998.
A newer version of this standard is available.
View Current Edition