AS/NZS 4184.2.3:1994
Withdrawn
Evaluation and routine testing in medical imaging departments Constancy tests - Darkroom safelight conditions
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
05-16-1994
06-30-2017
Applies to darkrooms in X-ray facilities where the image is processed either on film or by electronic means. It is identical with and reproduced from IEC 1223-2-3:1993.
| Committee |
HE-003
|
| DocumentType |
Standard
|
| ISBN |
0 7262 8835 7
|
| Pages |
11
|
| PublisherName |
Standards Australia
|
| Status |
Withdrawn
|
This technical report applies to darkrooms in X-ray facilities where any of the following unprocessed radiographic or photographic materials sensitive to light are handled:û all types of SCREEN FILM;û NON-SCREEN FILM;û photographic film for INDIRECT RADIOGRAPHY, as used for recording:- OUTPUT IMAGES of X-RAY IMAGE INTENSIFIERS; + other RADIOLOGICAL IMAGES after TRANSFER;û photographic material for copying RADIOGRAMS;û photographic material for making permanent images of information recorded by electronic means, and presented on display tubes; for example: using hard copy cameras, or printed by other electronic means, for example: laser; or used in diagnostic equipment, such as for general RECONSTRUCTIVE TOMOGRAPHY; digital imaging; ultra sound; magnetic resonance techniques; in NUCLEAR MEDICINE.This technical report is a part of a series of Particular Publications (standards and technical reports) which will describe test methods for the constancy of properties of various subsystems of diagnostic X-RAY EQUIPMENT, as described in IEC 1223-1.
| Standards | Relationship |
| IEC TS 61223-2-3:1993 | Identical |
First published as Joint Standard AS/NZS 4184.2.3:1994.
| AS/NZS 4184.2.1:1994 | Evaluation and routine testing in medical imaging departments Constancy tests - Film processors (Reconfirmed 2022) |
| AS/NZS 4184.1:1994 | Evaluation and routine testing in medical imaging departments General aspects (Reconfirmed 2022) |
| AS/NZS 4184.2.1:1994 | Evaluation and routine testing in medical imaging departments Constancy tests - Film processors (Reconfirmed 2022) |
| AS/NZS 4184.2.2:1994 | Evaluation and routine testing in medical imaging departments Constancy tests - Radiographic cassettes and film changers - Film-screen contact and relative sensitivity of the screen-cassette assembly |
| AS/NZS 4184.2.4:1995 | Evaluation and routine testing in medical imaging departments Constancy tests - Hard copy cameras |
| AS/NZS 4184.2.6:1995 | Evaluation and routine testing in medical imaging departments Constancy tests - X-ray equipment for computed tomography |
| AS/NZS 4184.2.5:1995 | Evaluation and routine testing in medical imaging departments Constancy tests - Image display devices |
| AS/NZS 4184.3.2:1998 | Evaluation and routine testing in medical imaging departments Acceptance tests - Imaging performance of mammographic X-ray equipment |