AS/NZS 4776.1.1:2008

Withdrawn

Withdrawn

Liquid-chilling packages using the vapour compression cycle Method of rating and testing for performance - Rating

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

11-14-2008

Withdrawn date

03-06-2020

US$32.34
Excluding Tax where applicable

1 - AS/NZS 4776.1.1:2008 LIQUID-CHILLING PACKAGES USING THE VAPOUR COMPRESSION CYCLE - METHOD OF RATING AND TESTING FOR...
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 OBJECTIVE
6 - 3 NORMATIVE REFERENCES
6 - 4 DEFINITIONS
6 - 4.1 Air-cooled condenser
6 - 4.2 Bubble point
7 - 4.3 Coefficient of performance (COP)
7 - 4.4 Condenser heat rejection capacity
7 - 4.5 Cooling capacity
7 - 4.6 Dew point
7 - 4.7 Evaporator
7 - 4.8 Fouling factor
7 - 4.9 Fouling factor allowance
7 - 4.10 Liquid-chilling package
7 - 4.11 Liquid-cooled condenser
7 - 4.12 Liquid refrigerant temperature
7 - 4.13 Part-load value (PLV)
7 - 4.14 Part-load value, integrated (IPLV)
7 - 4.15 Part-load value, non-standard (NPLV)
8 - 4.16 Saturated discharge temperature
8 - 4.17 Total power input
8 - 4.18 Published ratings
8 - 5 RATING REQUIREMENTS
8 - 5.1 Test requirements
8 - 5.2 Standard rating conditions
8 - 5.3 Application rating conditions
8 - 5.4 Part-load rating
9 - 5.5 Determination of part-load performance
10 - 6 PUBLISHED RATINGS
10 - 6.1 Compliance
10 - 6.2 Fouling allowance
11 - 6.3 Standard ratings
11 - 6.4 Nameplate information
12 - 7 RATING TOLERANCES
12 - 7.1 General
12 - 7.2 Allowable tolerance
12 - 7.3 Full-load example in COP
12 - 7.4 Part-load example in COP

Establishes methods of rating the performance of factory-made liquid-chilling packages using the vapour compression cycle.

Committee
ME-086
DocumentType
Standard
ISBN
0 7337 8935 8
Pages
7
ProductNote
Withdrawn 6-03-2020.
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This Standard sets out a procedure for rating liquid-chilling packages used in applications with temperatures as described in Clause 5.3 and as defined in Clause 4.12. This Standard covers air- and water-cooled liquid-chilling packages of cooling capacity 350 kW and above.This Standard does not cover - (a) liquid-chilling packages driven by other than electric motors;(b) air-cooled liquid-chilling packages with centrifugal fans;(c) liquid-chilling packages with remote condensers; and(d) liquid-chilling packages for fluids other than water.This Standard covers full-load and part-load ratings to allow for an energy analysis of the unit in different applications.

First published as AS/NZS 4776.1.1:2008.