AS/NZS 60265.1:2001
Current
High-voltage switches Switches for rated voltages above 1 kV and less than 52 kV (IEC 60265-1:1998, MOD) (Reconfirmed 2016)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
10-17-2001
Applies to three-phase a.c. switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from 16 2/3 Hz up to and including 60 Hz. Is also applicable to the operating devices of these switches and to their auxiliary equipment. It is intended to be read in conjunction with AS/NZS 2650. This Standard is technically equivalent to and contains the full content of IEC 60265:1998 and its Corrigendum:2000.
| Committee |
EL-007
|
| DocumentType |
Standard
|
| ISBN |
0 7337 4110 X
|
| Pages |
47
|
| ProductNote |
Reconfirmed 29/07/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 29/07/2016
|
| PublisherName |
Standards Australia
|
| Status |
Current
|
| Supersedes |
This Part of IEC 60265 is applicable to three-phase, alternating current switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from16 2/3 Hz up to and including 60 Hz.This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.Switch-disconnectors are also covered by IEC 60129.General principles and provisions of this standard may also be applicable to single pole switches intended for application in single-phase systems. The requirements for dielectric tests and making and breaking tests should be in accordance with the requirements of the specific application.NOTE 1 –Except where special clarification is required, the term “switch” is used to refer to all kinds of switches and switch-disconnectors within the scope of this standard.NOTE 2 –Earthing switches are not covered by this standard. Earthing switches forming an integral Part of a switch are covered by IEC 60129.NOTE 3 –This standard is not applicable to switching devices attached as an accessory to a high-voltage fuse assembly or its mounting and operated by opening and closing the fuse assembly.
First published as AS C339-1967.
Revised and redesignated as AS 1025-1971.
Second edition 1979.
Revised and redesignated as AS 1025.1-1984.
Jointly revised and redesignated AS/NZS 60265.1:2001.