ASHRAE 23.1 : 2010
Superseded
View Superseded by
METHODS OF TESTING FOR RATING THE PERFORMANCE OF POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS AND CONDENSING UNITS THAT OPERATE AT SUBCRITICAL TEMPERATURES OF THE REFRIGERANT
Hardcopy , PDF
English
07-18-2018
07-24-2019
Foreword
1 Purpose
2 Scope
3 Definitions
4 Classifications
5 Requirements
6 Instruments
7 Methods of Testing
8 Compressor Testing
9 Condensing Unit Testing
10 References
Describes methods of testing for rating the thermodynamic performance of positive displacement refrigerant compressors and condensing units that operate at subcritical temperatures of the refrigerant.
| Committee |
TC 8.1
|
| DevelopmentNote |
Supersedes ASHRAE 23. (05/2010)
|
| DocumentType |
Standard
|
| Pages |
16
|
| PublisherName |
American Society of Heating, Refrigerating & Air Conditioning Engineers
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This standard applies to the methods of testing for ratingthe thermodynamic performance of single-stage positive-displacement refrigerant compressors and condensingunits that operate at subcritical temperatures of the refrigerantwhich either (a) do not have liquid injection or (b) incorporateliquid injection that is achieved by compressor motorpower.
| BS ISO 9459-4:2013 | Solar heating. Domestic water heating systems System performance characterization by means of component tests and computer simulation |
| ASHRAE 41.4 : 2015 | STANDARD METHOD FOR MEASURING THE PROPORTION OF LUBRICANT IN LIQUID REFRIGERANT |
| ASHRAE HDBK REFRIGERATION : 2014 | ASHRAE HANDBOOK - REFRIGERATION |
| AHRI 1251 (SI) : 2014 | PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS |
| AHRI 1250 (I-P) : 2014 | PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS |
| AHRI 545 : 2017 | PERFORMANCE RATING OF MODULATING POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS |
| ISO 9459-4:2013 | Solar heating — Domestic water heating systems — Part 4: System performance characterization by means of component tests and computer simulation |
| AHRI 570 (I-P) : 2012 | PERFORMANCE RATING OF POSITIVE DISPLACEMENT CARBON DIOXIDE REFRIGERANT COMPRESSORS AND COMPRESSOR UNITS |
| AHRI 571 (SI) : 2012 | PERFORMANCE RATING OF POSITIVE DISPLACEMENT CARBON DIOXIDE REFRIGERANT COMPRESSORS AND COMPRESSOR UNITS |
| AHRI 540 : 2004 | PERFORMANCE RATING OF POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS AND COMPRESSOR UNITS |
| ASHRAE 41.1 : 2013 | STANDARD METHOD FOR TEMPERATURE MEASUREMENT |
| ASHRAE 41.9 : 2011 | STANDARD METHODS FOR VOLATILE-REFRIGERANT MASS FLOW MEASUREMENTS USING CALORIMETERS |
| ASHRAE 41.10 : 2013 | METHODS FOR REFRIGERANT MASS FLOW MEASUREMENT USING FLOWMETERS |
| ASME PTC19.3 : 1974(R2004) | PERFORMANCE TEST CODE - PART 3: TEMPERATURE MEASUREMENT |
| ASHRAE 41.3 : 2014 | METHODS FOR PRESSURE MEASUREMENT |
| ASHRAE 34 : 2013 | DESIGNATION AND SAFETY CLASSIFICATION OF REFRIGERANTS |
| ASHRAE 15 : 2013 | SAFETY STANDARD FOR REFRIGERATION SYSTEMS |