Standard Guide for Characterization of Type I Collagen as Starting Material for Surgical Implants and Substrates for Tissue Engineered Medical Products (TEMPs)

Available format(s)

Hardcopy , PDF

Superseded date

12-05-2019

Language(s)

English

Published date

04-01-2011

1.1 This guide for characterizing collagen-containing biomaterials is intended to provide characteristics, properties, and test methods for use by producers, manufacturers, and researchers to more clearly identify the specific collagen materials used. With greater than 20 types of collagen and the different properties of each, a single document would be cumbersome. This guide will focus on the characterization of Type I collagen, which is the most abundant collagen in mammals, especially in skin and bone. Collagen isolated from these sources may contain other types of collagen, for example, Type III and Type V. This guide does not provide specific parameters for any collagen product or mix of products or the acceptability of those products for the intended use. The collagen may be from any source, including, but not limited to, animal or cadaveric sources, human cell culture, or recombinant sources. The biological, immunological, or toxicological properties of the collagen may vary, depending on the source material. The properties of the collagen prepared from each of the above sources must be thoroughly investigated, as the changes in the collagen properties as a function of source materials is not thoroughly understood. This guide is intended to focus on purified Type I collagen as a starting material for surgical implants and substrates for tissue engineered medical products (TEMPs); some methods may not be applicable for gelatin or tissue implants. This guide may serve as a template for characterization of other types of collagen.

1.2 The biological response to collagen in soft tissue has been well documented by a history of clinical use (1, 2) and laboratory studies (3, 4, 5, 6). Biocompatibility and appropriateness of use for a specific application(s) is the responsibility of the product manufacturer.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 WarningMercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPAs website (http://www.epa.gov/mercury/faq.htm) for additional information. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited by state law.

1.5 The following precautionary caveat pertains only to the test method portion, Section 5, of this guide. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Committee
F 04
DocumentType
Guide
Pages
13
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM F 2027 : 2016 Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products
ASTM F 2150 : 2013 Standard Guide for Characterization and Testing of Biomaterial Scaffolds Used in Tissue-Engineered Medical Products
ASTM F 3225 : 2017 Standard Guide for Characterization and Assessment of Vascular Graft Tissue Engineered Medical Products (TEMPs)
ASTM F 3223 : 2017 Standard Guide for Characterization and Assessment of Tissue Engineered Medical Products (TEMPs) for Knee Meniscus Surgical Repair and/or Reconstruction
ASTM F 2903 : 2011 Standard Guide for Tissue Engineered Medical Products (TEMPs) for Reinforcement of Tendon and Ligament Surgical Repair (Withdrawn 2020)

ASTM F 1251 : 1989 : R1995 Standard Terminology Relating to Polymeric Biomaterials in Medical and Surgical Devices
ASTM F 1904 : 1998 : R2003 Standard Practice for Testing the Biological Responses to Particles In Vivo
ASTM F 1983 : 1999 : R2008 Standard Practice for Assessment of Compatibility of Absorbable/Resorbable Biomaterials for Implant Applications
ASTM F 1439 : 2003 Standard Guide for Performance of Lifetime Bioassay for the Tumorigenic Potential of Implant Materials
ASTM F 1983 : 1999 : R2003 Standard Practice for Assessment of Compatibiltiy of Absorbable/Resorbable Biomaterials for Implant Applications
ASTM F 1906 : 1998 Standard Practice for Evaluation of Immune Responses In Biocompatibility Testing Using ELISA Tests, Lymphocyte, Proliferation, and Cell Migration
ASTM F 1904 : 1998 : EDT 1 Standard Practice for Testing the Biological Responses to Particles In Vivo
ASTM F 2148 : 2006 : REV A Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
ASTM F 1903 : 2010 Standard Practice for Testing For Biological Responses to Particles <i>In Vitro</i>
ASTM F 2148 : 2013 Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
ASTM F 1439 : 2003 : R2008 Standard Guide for Performance of Lifetime Bioassay for the Tumorigenic Potential of Implant Materials
ASTM F 1904 : 2014 Standard Practice for Testing the Biological Responses to Particles <emph type="bdit" >in vivo</emph>
ASTM F 1905 : 1998 Standard Practice for Selecting Tests for Determining the Propensity of Materials to Cause Immunotoxicity
ASTM F 2148 : 2007 Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
ASTM F 2148 : 2018 Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
ASTM F 2148 : 2007 : R2012 Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
ASTM F 2148 : 2007 : EDT 1 Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
ASTM F 1439 : 2003 : R2018 Standard Guide for Performance of Lifetime Bioassay for the Tumorigenic Potential of Implant Materials
ASTM E 1298 : 1989 : R2000 Standard Guide for Determination of Purity, Impurities, and Contaminants in Biological Drug Products
ASTM E 1298 : 1989 : R1994 Standard Guide for Determination of Purity, Impurities, and Contaminants in Biological Drug Products
ASTM F 1904 : 1998 : R2008 Standard Practice for Testing the Biological Responses to Particles <i>in vivo</i>
ASTM F 2148 : 2001 Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
ASTM E 1298 : 2006 Standard Guide for Determination of Purity, Impurities, and Contaminants in Biological Drug Products (Withdrawn 2014)
ASTM F 1903 : 1998 Standard Practice for Testing for Biological Responses to Particles In Vitro
ASTM F 1905 : 1998 : R2003 Standard Practice for Selecting Tests for Determining the Propensity of Materials to Cause Immunotoxicity (Withdrawn 2011)
ASTM F 1439 : 2002 Standard Guide for Performance of Lifetime Bioassay for the Tumorigenic Potential of Implant Materials
ASTM F 1903 : 2018 Standard Practice for Testing for Cellular Responses to Particles <emph type="bdit" >in vitro</emph>
ASTM F 1983 : 2014 Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications
ASTM F 1906 : 1998 : R2003 Standard Practice for Evaluation of Immune Responses In Biocompatibility Testing Using ELISA Tests, Lymphocyte, Proliferation, and Cell Migration (Withdrawn 2011)
ASTM F 1439 : 1992 : R1996 Standard Guide for Performance of Lifetime Bioassay for the Tumorigenic Potential of Implant Materials
ASTM F 1251 : 1989 : R2003 Standard Terminology Relating to Polymeric Biomaterials in Medical and Surgical Devices (Withdrawn 2012)
ASTM F 1439 : 2003 : R2013 Standard Guide for Performance of Lifetime Bioassay for the Tumorigenic Potential of Implant Materials
ASTM F 1983 : 1999 Standard Practice for Assessment of Compatibiltiy of Absorbable/Resorbable Biomaterials for Implant Applications

View more information
US$83.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.