BS 2782-5:Method 540B:1982
Superseded
View Superseded by
Methods of testing plastics. Optical and colour properties, weathering Methods of exposure to laboratory light sources, (xenon arc lamp, enclosed carbon arc lamp, open-flame carbon arc lamp, fluorescent tube lamps)
Hardcopy , PDF
English
02-26-1982
09-15-1995
National foreword
Method
0 Introduction
1 Scope
2 Field of application
3 References
4 Principle
5 Apparatus
6 Test specimens
7 Procedure
8 Test report
Annexes
A Correlation of the effects of exposure to artificial
light sources and exposure to natural daylight
B Use of blue dyed wool standards to measure light
dosage
C Spectral distribution of simulated solar radiation
D Information concerning exposure to the light from
fluorescent tube lamps
Tables
1 Spray cycles
2 Exposure stages
3 Characteristics of fluorescent lamps
Figures
1 Spectral distribution - Lamp A
2 Spectral distribution - Lamp B
3 Spectral distribution - Lamp C
4 Spectral distribution - Lamp D
5 Spectral distribution - Lamp E
Gives methods for exposing specimens to laboratory light sources in order to assess changes produced by such exposure using xenon arc lamp, enclosed carbon arc lamp, and open-flame carbon arc lamp plus means of determining radiation dosage. The xenon arc, when correctly filtered and maintained, yields a spectrum most closely approximating to that of daylight but carbon arc sources are considerably different from daylight and their use is decreasing. Includes correlation of the effects of exposure to artificial light sources and natural daylight, use of blue dyed wool standards to measure light dosage, spectral distribution of simulated solar radiation and information concerning exposure to the light from fluorescent tube lamps.
| Committee |
PRI/21
|
| DevelopmentNote |
Also numbered as ISO 4892 Inactive for the new design. Superseded by BS 2782-5.540D(1995), BS 2782-5.540E(1995), BS 2782-5.540F(1995) & BS 2782-5.540G(1995) but remains current. Supersedes method 507B of BS 2782(1970) & 78/55059 DC (06/2003)
|
| DocumentType |
Standard
|
| Pages |
24
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This International Standard specifies methods for exposing specimens to laboratory light sources in order to assess changes produced by such exposure.
The following types of light source are included:
- xenon arc lamp;
- enclosed carbon arc lamp;
- open-flame carbon arc lamp.
Of the different light sources, the xenon arc is advantageous in that it can, when correctly filtered and maintained, yield a spectrum most closely approximating to that of daylight. The carbon arc sources yield light which is considerably different from daylight and their use is decreasing. However, they have been found useful for some specific purposes and are still in considerable use in some countries; for this reason they have been included in this International Standard.
This International Standard also specifies means of determining radiation dosage.
For the method of determination of changes in properties after exposure, reference is made to ISO 4582.
A newer version of this standard is available.
View Current Edition View Current Edition View Current Edition View Current Edition