1. General
1.1 Scope
1.2 Terminology
2. Direct operated pressure gauge level meter
3. Bubbler-type level meter
3.1 Description
3.2 Installation requirements
3.3 Gas supply
3.4 Accuracy
4. Pressure bulb level meter
4.1 Description
4.2 Installation
4.3 Uncertainty of measurement
5. Indicating and recording instruments
5.1 General
6. Choice of meter
Tables
1. Accuracy of measurements of head as a percentage
of actual head
2. The relation between the diameter of connecting
tubing and bulb diameter
Figures
1. Pressure gauge type level meter
2. Bubbler-type level meter for corrosive liquids,
non-corrosive liquids and liquids with solids in
suspension
3. Pressure bulb type level meter
Provides information on the installation and use of equipment for the measurement of liquid level by means of a pressure signal generated at a point below the liquid surface. Describes bubbler-type and pressure bulb level meters.