BS 5268-4.2:1990
Superseded
View Superseded by
Structural use of timber. Fire resistance of timber structures Recommendations for calculating fire resistance of timber stud walls and joisted floor constructions
Hardcopy , PDF
English
04-30-1990
03-30-2010
Foreword
Committees responsible
Recommendations
1 Scope
2 Definitions
3 Fire resistance criteria
4 Materials
5 Construction details
6 Calculation method
Appendix
A Worked examples
Tables
1 Internal walls required to provide a fire resistance
performance of 30:30:30 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from one side at a time
2 Internal walls required to provide a fire resistance
performance of 60:60:60 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from one side at a time
3 Internal walls required to provide a fire resistance
performance of 60:60:60 min. Double leaf walls of
symmetrical/asymmetrical construction exposed to
fire from either side
4 External walls required to provide a fire resistance
performance of 30:30:15 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from the inside only
5 External walls required to provide a fire resistance
performance of 30:30:30 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from one side
6 External walls required to provide a fire resistance
performance of 60:60:60 min and 60:60:15 min. Single
leaf walls of symmetrical/asymmetrical construction
exposed to fire from one side at a time
7 Specification of materials and conditions of fixings
for walls
8 Timber floors, concealed joists, required to provide
fire resistance performance of 30:15:15 min and
30:30:30 min
9 Timber floors, concealed joists, required to provide
a fire resistance performance of 60:60:60 min
10 Timber floors, exposed joists, required to provide a
fire resistance performance of 30:30:30 min
11 Specification of materials and conditions of fixing
for floors
Figures
1 Diagram showing depth x breadth of stud and breadth
of joist
2 Profiles for tongued and grooved ceiling boards
3 Methods of fixing insulation materials in walls
4 Methods of fixing insulation materials in floors
5 Method of fixing ceiling linings to exposed joists
Extends the code given in Section 4.1 of BS 5268 to include composite timber elements.
| Committee |
B/525/5
|
| DevelopmentNote |
Supersedes 86/14933 DC. (07/2005) Reviewed and confirmed by BSI, November 2007. (10/2007)
|
| DocumentType |
Standard
|
| Pages |
28
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
| BS EN 1995-1-2 NA : 2004 | UK NATIONAL ANNEX TO EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-2: GENERAL - STRUCTURAL FIRE DESIGN |
| 07/30147204 DC : 0 | BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS |
| BS 5588-8:1999 | Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people |
| BS 5268-2:1991 | Structural use of timber Code of practice for permissible stress design, materials and workmanship |
| BS 476-10:2009 | Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs |
| BS 5268-2:2002 | Structural use of timber Code of practice for permissible stress design, materials and workmanship |
| PD 7974-3:2003 | Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin (Sub-system 3) |
| PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
| BS 5588-11:1997 | Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
| BS 5268-6.1:1996 | Structural use of timber Code of practice for timber frame walls - Dwellings not exceeding seven storeys |
| I.S. 444:1998 | THE USE OF STRUCTURAL TIMBER IN BUILDINGS |
| BS 476-23:1987 | Fire tests on building materials and structures Methods for determination of the contribution of components to the fire resistance of a structure |
| BS 1142-2:1971 | Specification for fibre building boards Medium board, medium density fibreboard (MDF) and hardboard |
| BS 3536-1:1962 | Specification for asbestos insulating boards and asbestos wallboards. Imperial units |
| BS 473(1971) : AMD 3695 | SPECIFICATION FOR CONCRETE ROOFING TILES AND FITTINGS |
| BS 5268-4.1:1978 | Structural use of timber. Fire resistance of timber structures Recommendations for calculating fire resistance of timber members |
| BS 3536-2:1974 | Specification for asbestos insulating boards and asbestos wallboards Metric units |
| BS 4471:1987 | Specification for sizes of sawn and processed softwood |
| BS CP112(1967) : LATEST | PRESERVATIVE TREATMENTS FOR TIMBER USED IN BUILDINGS |
| BS 5669:1979 | Specification for wood chipboard and methods of test for particle board |
| BS 1142-3:1972 | Specification for fibre building boards Insulating board (softboard) |
| BS 476-20:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles) |
| BS 476-21:1987 | Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction |
| BS 6214:1982 | Specification for jointing materials for plasterboard |
| BS 1191-1:1973 | Specification for gypsum building plasters Excluding premixed lightweight plasters |
| BS 5803-1:1985 | Thermal insulation for use in pitched roof spaces in dwellings Specification for man-made mineral fibre thermal insulation mats |
| BS 550(1971) : AMD 3695 | SPECIFICATION FOR CONCRETE ROOFING TILES AND FITTINGS |
| BS 1230-1:1985 | Gypsum plasterboard Specification for plasterboard excluding materials submitted to secondary operations |
| BS 5268-6.1(1988) : 1988 | STRUCTURAL USE OF TIMBER - CODE OF PRACTICE FOR TIMBER FRAME WALLS - DWELLINGS NOT EXCEEDING THREE STOREYS |
| BS 1369:1947 | Specification for metal lathing (steel) for plastering |
| BS 402:1979 | Specification for clay plain roofing tiles and fittings |
| BS 1191-2:1973 | Specification for gypsum building plasters Premixed lightweight plasters |
| BS 476-8:1972 | Fire tests on building materials and structures Test methods and criteria for the fire resistance of elements of building construction |
| BS 4422-2:1971 | Glossary of terms associated with fire Building materials and structures |
| BS 405:1987 | Specification for uncoated expanded metal carbon steel sheets for general purposes |
| BS 476-22:1987 | Fire tests on building materials and structures Methods for determination of the fire resistance of non-loadbearing elements of construction |