BS 5588-4:1978
Superseded
View Superseded by
Fire precautions in the design, construction and use of buildings Code of practice for smoke control in protected escape routes using pressurization
Hardcopy , PDF
English
06-30-1978
03-15-1998
Foreword
Drafting committee
Code
1 Scope
2 References
3 Definitions
4 The building
5 The system
6 The installation and equipment
7 General
Appendix
A A worked example
Tables
1 Pressurization levels
2 Values of (P) to the power 1/N for N = 2 and N = 1.6
3 Typical leakage areas for four types of door
4 Air leakage data for doors
5 Air leakage data for windows
6 Values of factor F for various vent sizes
7 Values of K
8 Airflow through an open door: staircase only
pressurized: staircase/accommodation door open
9 Airflow through an open door: staircase and lift
lobby pressurized to same level: airflow when one
lobby/accommodation door is open
10 Airflow through two open doors: staircase and lift
lobby pressured to the same level: two lobby doors
(stairwell/lobby and lobby/accommodation) open on
same floor
11 Minimum total length of window cracks (per floor)
for satisfactory venting of the pressurizing air
12 Suggestions for choice of venting system
Figures
1 Pressurizing staircase only
2 Deleted
3 Pressurizing staircase and lift lobby
4 Leakage paths in series
5 Leakage paths in parallel
6 Steps in obtaining the equivalent resistance of a
combination of series and parallel paths of air
leakage
7 Diagram of leakage from lift landing doors
8 Diagram of airflow conditions listed in table 8
9 Diagram of airflow conditions listed in table 9
10 Diagram of airflow conditions listed in table 10
11 Plan of building for worked example
Recommendations for a method for keeping protected escape routes in buildings clear of smoke by pressurizing the escape routes. The method is an alternative to the natural ventilation required by CP 3:Ch IV and certain building acts and regulations.
| Committee |
FSH/14
|
| DevelopmentNote |
BS DRAFT 92/39700 DC
|
| DocumentType |
Standard
|
| Pages |
46
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
| BS 5588-11:1997 | Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
| BS 5588-1:1990 | Fire precautions in the design, construction and use of buildings Code of practice for residential buildings |
| BS 5720:1979 | Code of practice for mechanical ventilation and air conditioning in buildings |
| BS 5588-10:1991 | Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes |
| BS 5588-6:1991 | Fire precautions in the design, construction and use of buildings Code of practice for places of assembly |
| BS 5588-2:1985 | Fire precautions in the design, construction and use of buildings Code of practice for shops |
| BS 5588-7:1997 | Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings |
| BS 5588-5:1991 | Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts |
| BS 6701-1:1990 | Code of practice for installation of apparatus intended for connection to certain telecommunication systems General recommendations |
| BS 7083:1996 | Guide to the accommodation and operating environment for information technology (IT) equipment |
| BS 5588-9:1989 | Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork |
| BS 8200:1985 | Code of practice for design of non-loadbearing external vertical enclosures of buildings |
| BS 5588-5:1986 | Fire precautions in the design and construction of buildings. Code of practice for firefighting stairways and lifts |
| BS 6701-1:1986 | Code of practice for installation of apparatus intended for connection to certain telecommunication systems General recommendations |
| BS 5588-3:1983 | Fire precautions in the design, construction and use of buildings Code of practice for office buildings |
| BS 5234-1:1992 | Partitions (including matching linings) Code of practice for design and installation |
| BS 5588-2:1985 | Fire precautions in the design, construction and use of buildings Code of practice for shops |
| BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
| BS 5588-3:1983 | Fire precautions in the design, construction and use of buildings Code of practice for office buildings |
| BS CP3:CH4-1(1971) : AMD 2708 | CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - PRECAUTIONS AGAINST FIRE - FLATS AND MAISONETTES - (IN BLOCKS OVER TWO STOREYS) |
| BS 5588-1:1990 | Fire precautions in the design, construction and use of buildings Code of practice for residential buildings |