Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General
4.1 Upgrading the safety of existing lifts
4.2 Risk assessment
4.3 Upgrading of existing CE marked lifts
4.4 Tests and records of important modifications
5 Modification to existing lifts
5.1 Change of rated speed
5.2 Change of rated load
5.3 Change of travel
5.4 Change of mass of empty car, mass of jack or mass of
suspension means
5.5 Change of complete controller including door operations
5.6 Change of drive controller
5.7 Change of traffic controller
5.8 Change from manual to power-operated doors
5.9 Change to entrances
5.10 Change of a safety component
5.11 Change of electric safety devices
5.12 Change of the jack and lift machine
5.13 Change of a car enclosure and/or interior finishes
5.14 Change of door operator
5.15 Change from gates to doors
5.16 Change of guide rails or type of guide rails
Annex A (informative) Relevant statutory regulations
Annex B (informative) Summary of significant hazards
Bibliography
Gives recommendations for the modernization, or modification, and improvement of hydraulic passenger and goods passenger lifts, serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by jacks, ropes or chains and moving between guide rails inclined not more than 15 degree to the vertical.
| Committee |
MHE/4
|
| DevelopmentNote |
Supersedes BS 5655-12(1989) and 05/30128013 DC. (01/2006) Reviewed and confirmed by BSI, January 2012. (12/2011)
|
| DocumentType |
Standard
|
| Pages |
38
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of BS 5655 gives recommendations for the modernization, or modification, and improvement of hydraulic passenger and goods passenger lifts, serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by jacks, ropes or chains and moving between guide rails inclined not more than 15° to the vertical.
This part of BS 5655 does not cover any of the following types of lift:
- new lifts (see Note 2);
- lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ship’s hoists, platforms for exploration or drilling at sea, construction and maintenance appliances;
- installations where the inclination of the guide rails to the vertical exceeds 15°;
- lifts with drives other than hydraulic lifts suspended by jacks, ropes or chains;
- like-for-like replacement of lift components (see 3.2);
- goods only lifts;
- lifts with rated speeds, upwards or downwards, greater than 1.0 m/s.
NOTE 1 The recommendations in this part of BS 5655 may, however, be used as a basis for modernization or modification of such lifts.
NOTE 2 Where a lift falls into one of the following categories, it is deemed to be a new lift as defined in the Lifts Regulations 1997 [1] and this part of BS 5655 is not applicable:
- dismantled from an existing site and installed at a new site;
- installed where no lift previously existed;
- completely replaced;
- only retains the guide rails.
NOTE 3 In some situations (e.g. potentially explosive atmosphere, extreme climate conditions, vandalism, transporting dangerous goods, etc.), additional measures might need to be taken to those recommended in this part of BS 5655.