BS 6400-2:2006

Withdrawn

Withdrawn

View Superseded by

Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m3/h Medium pressure (2nd family gases)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

10-31-2006

Withdrawn date

01-03-2019

Superseded by

BS 6400-2:2018

US$473.61
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Planning and exchange of information
5 Competency
6 Design
7 Gas transporter's appraisal of a primary meter installation
8 Fitting a meter installation
9 Testing, purging and commissioning of the regulator
   assembly
10 Fitting, testing and purging the meter
11 Commissioning of the meter installation
12 Notices
13 Meter exchange and/or replacement of other gas
   fittings
14 Meter relocation
15 Meter removal
16 Records
17 Post installation checks
Annexes
Annex A (normative) Sizing of meters
Annex B (normative) Operating pressure limits
Annex C (normative) Testing, purging and commissioning of the
                    regulator assembly
Bibliography

Defines requirements for the installation, exchange, relocation and removal of credit or prepayment diaphragm and ultrasonic gas meters with a maximum capacity not exceeding 6 m[3]/h.

Committee
GSE/30
DevelopmentNote
Supersedes 05/30086662 DC. (08/2006) Together with BS 6400-1(2006) and BS 6400-3(2007) supersedes BS 6400(1997). (12/2007) Reviewed and confirmed by BSI, December 2011. (11/2011)
DocumentType
Standard
Pages
64
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

10/30213917 DC : 0 BS 8660-1 - GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES
BS 5546:2010 Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net
13/30261683 DC : 0 BS 6798 - SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
BS 6798:2009 Specification for installation and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
BS 6891:2015 Specification for the installation and maintenance of low pressure gas installation pipework of up to 35 mm (R1¼) on premises
BS 6798:2014 Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
09/30166542 DC : 0 BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET
BS 8660-1:2011 Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances
BS 6400-3:2007 Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Low and medium pressure (3rd family gases)

BS EN 437 : 2003 TEST GASES - TEST PRESSURES - APPLIANCE CATEGORIES
BS 4161-5:1990 Gas meters Specification for diaphragm meters for working pressures up to 7 bar
DD ENV 14236:2002 Ultrasonic domestic gas meters
BS EN 12279:2000 Gas supply systems. Gas pressure regulating installations on service lines. Functional requirements
BS 6004:2000 Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring
BS EN 1359:2017 Gas meters. Diaphragm gas meters
BS EN 1057 : 2006 COPPER AND COPPER ALLOYS - SEAMLESS, ROUND COPPER TUBES FOR WATER AND GAS IN SANITARY AND HEATING APPLICATIONS
BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
BS EN ISO 10806:2003 Pipework. Fittings for corrugated metal hoses
BS EN 1775:2007 Gas supply. Gas pipework for buildings. Maximum operating pressure less than or equal to 5 bar. Functional recommendations

US$473.61
Excluding Tax where applicable